Safety Light Curtain
101
5.2.6.2 Display Settings
• The display setting can be adjusted so that it does not interfere during operation (e.g. at manual work sta-
tions).
• The following settings can be selected:
Standard
Energy saving mode
LEDs
Always active according to status
Always active according to status
Activation segment display
Automatic
Any key pressed or change via a
status message
Display duration segment display
Permanent
30 s
Selection
Via parameter configuration
Default Settings
5.2.6.3 Signal Output
• Pin 6 of the IO-Link output is on the system connection of the receiver. If IO-Link communication is not
active, this output can be used as a digital PNP output (signal output).
• The following functions can be assigned to the signal output:
ATTENTION!
On the receiver of the ESPE, Pin 6 (IO-Link output) is not suitable for safety-related use.
Function
Signal active
Signal inactive
Acknowledgment prompt
(default setting)
Acknowledgment required (e.g.
following safety field penetration
with restart inhibit)
No acknowledgment (e.g. with
automatic restart)
OSSD switching states
OSSDs ON
OSSDs OFF
Muting status
Muting active
No muting active
Contamination warning
Contamination or weak signal
Good signal strength
Synchronous run
Receiver is in synchronous run.
Receiver is not in synchronous
run, e.g. because:
• Safety field is fully covered,
• Incorrect alignment,
• Emitter not in operation.
Ready state
ESPE ready for operation
ESPE is ready state
Off
Output is deactivated.