Operation
160
The display is laid out as follows:
Digit 1
Digit 2
Digit 3
Digit 4
Status displays during muting
If muting is parametrized, information on the current muting sequence and diagnostic information can be
read off the segment display.
This information is shown as follows:
Input 3
Input 1
Input 4
Input 2
Muting active
SYNC
The following rules apply:
• M in the first digit indicates that a muting error is present. The meaning of the error is indicated by a code in
the following digits.
• The fourth digit shows the current muting status.
• For explanations of the diagnostic codes, see
Meaning of the displays in the fourth digit
E1 (MS3 / belt stop / Full
Muting Enable)
E2 (MS4 / Muting
Enable)
E3 (MS1)
E4 (MS2)
Muting active