Safety Light Curtain
133
OSSD
RES
SIG LOW
ERROR
Switch off
• The “partial muting” function limits the impact of muting to a
partial area of the safety field.
– OFF: No partial muting.
– T-IN: Teach-in the relevant muting area.
• To do this, move an object of the desired size into the safety
field
.
• The display T000 shows the number of beams currently
blocked (e.g. T004
4 beams)
• 1 beam is automatically added to the actual object size at the
ends of the area to increase the availability through potential
tolerances.
• If no beam was blocked during the teach process, the pa-
rameter configuration is not applied.
• For more information on the “partial muting” function, see
OSSD
RES
SIG LOW
ERROR
Teach-in
OSSD
RES
SIG LOW
ERROR
Back
OSSD
RES
SIG LOW
ERROR
f) Full Muting Enable
OSSD
RES
SIG LOW
ERROR
Switch on
• The “Full Muting Enable” function is suitable for use, in conjunc-
tion with “partial muting”, for applications where the object height
varies.
– ON: Partial muting is lifted when a signal is applied and muting
acts on the entire safety field height.
– OFF: Partial muting is active without changes to the safety field
height.
• This function should only be used if “Partial Muting” was activat-
ed beforehand.
• For more information on the “Full Muting Enable” function, see
OSSD
RES
SIG LOW
ERROR
Switch off
OSSD
RES
SIG LOW
ERROR
Back
OSSD
RES
SIG LOW
ERROR
g) Gap suppression
OSSD
RES
SIG LOW
ERROR
Switch on
• For transport items with gaps, brief interruptions in the muting
signal are to be expected. The “gap suppression” function pre-
vents this from ending the muting function.
– ON: The muting signals (MS1...MS4) are delayed by 250ms.
– OFF: No delay of the muting signals
• For more information on the “gap suppression” function, see
OSSD
RES
SIG LOW
ERROR
Switch off
OSSD
RES
SIG LOW
ERROR
Back
OSSD
RES
SIG LOW
ERROR
h) Override