Diagnosis
166
13.3.2 Codes for General Errors
Code
Affected
components
Status
Description/cause
Measures
002
Emitter /
receiver
Temporary, restarts
after 2 s
Parameter configuration
request from normal op-
eration and error mode
003
Emitter /
receiver
Temporary, restarts
after 2 s
Parameter configuration
request from normal op-
eration and error mode
Application errors
E 010
Emitter /
receiver
Temporary, restarts after
12 s
Supply voltage too low
Make supply voltage
available within the
specified limits
E 011
Emitter /
receiver
Temporary, restarts after
12 s
Supply voltage too low
Make supply voltage
available within the
specified limits
E 012
Emitter /
receiver
Permanent
Supply voltage too high
Make supply voltage
available within the
specified limits
E 013
Emitter /
receiver
Permanent
Supply voltage too high
Make supply voltage
available within the
specified limits
E 020
Receiver
Permanent
OSSD A: Short to posi-
tive/ capacity too high
Resolve short to positive
E 021
Receiver
Permanent
OSSD A: Short to posi-
tive/ capacity too high
Resolve short to positive
E 022
Receiver
Permanent
OSSD A: Short to
ground/overload
Resolve short to ground
E 023
Receiver
Permanent
OSSD A: Short to
ground/overload
Resolve short to ground
E 024
Receiver
Permanent
OSSD B: Short to posi-
tive/ capacity too high
Resolve short to positive
E 025
Receiver
Permanent
OSSD B: Short to posi-
tive/ capacity too high
Resolve short to positive
E 026
Receiver
Permanent
OSSD B: Short to
ground/overload
Resolve short to ground
E 027
Receiver
Permanent
OSSD B: Short to
ground/overload
Resolve short to ground
E 028
Receiver
Permanent
Slave inputs: Different
switching status
Check slave connection,
inconsistent signals
E 029
Receiver
Permanent
Slave inputs: Different
switching status
Check slave connection,
inconsistent signals