![WEISS 3RT2017-1BB42 Manual Download Page 45](http://html.mh-extra.com/html/weiss/3rt2017-1bb42/3rt2017-1bb42_manual_953402045.webp)
Manual R06-2016
45 / 172
ROTARY INDEXING TABLE CONTROLLER
EF2...B
FUNCTION AND SIGNAL DESCRIPTIONS |
4.6 Interface assignment TM15
4.6
Interface assignment TM15
The Terminal Module provides 24 DI/DO (digital I/Os).
In the case of EF2, the digital inputs and outputs are permanently assigned as 12 DI and 12 DO.
4.6.1 Interface X520
4.6.2 Interface X521
Representation
Terminal
Name
1
L1+
2
DI 0
3
DI 1
4
DI 2
5
DI 3
6
DI 4
7
DI 5
8
DI 6
9
DI 7
10
M1 (GND)
Screw terminal
Max. connectable cross-section: 1.5 mm
2
L1+: A 24 V DC power supply for DI/DO 0 to 7 (first potential group) must always be connected if at least one
DI/DO in the potential group is used as an output.
M1: A ground reference for DI/DO 0 to 7 (first potential group) must always be connected if at least one DI/DO
in the potential group is used as an output
.
DI/DO: Digital input / output
Representation
Terminal
Name
1
L2+
2
DI 8
3
DI 9
4
DI 10
5
DI 11
6
DO 0
7
DO 1
8
DO 2
9
DO 3
10
M2 (GND)
Screw terminal
Max. connectable cross-section: 1.5 mm
2
L2+: A 24 V DC power supply for DI/DO 8 to 15 (second potential group) must always be connected if at least
one DI/DO of the potential group is used as an output.
M2: A ground reference for DI/DO 8 to 15 (second potential group) must always be connected if at least one
DI/DO of the potential group is used as an output
.
DI/DO: Digital input / output