![WEISS 3RT2017-1BB42 Manual Download Page 22](http://html.mh-extra.com/html/weiss/3rt2017-1bb42/3rt2017-1bb42_manual_953402022.webp)
Manual R06-2016
22 / 172
ROTARY INDEXING TABLE CONTROLLER EF2...B
COMPONENT DESCRIPTIONS |
3.1 Power Modules PM240-2
Refer to the device manual of the manufacturer for further information.
Dimensions
•
Width
•
Height
•
Depth
without operating unit
with operating unit
mm
mm
mm
mm
mm
73
196
165
248
73
196
165
248
73
196
165
248
100
291
165
248
Frame size
FSA
FSA
FSA
FSB
Weight
•
Without integrated line filter
•
With integrated line filter
kg
kg
1.4
1.6
1.4
1.5
1.4
1.5
2.9
3.1
1) The rated output current I
N
and the base-load current I
L
are based on the load cycle for low overload LO.
2) The base-load current I
H
is based on the load cycle for high overload HO.
3) Typical values. Further information in the Internet at http://support.automation.com/WW/view/de/94059311
4) The input current depends on the motor load and network impedance. The input currents are valid for loading
with rated power (based on I
N
) at a network impedance according to u
k
= 1%. The current values are displayed on
the rating plate of the power module.
Standard Power Modules PM240-2
•
Without integrated line filter
6SL3210-
1PB13-0UL0
6SL3210-
1PE16-1UL1
6SL3210-
1PE18-0UL1
6SL3210-
1PE21-1UL0
•
With integrated line filter
6SL3210-
1PB13-0AL0
6SL3210-
1PE16-1AL1
6SL3210-
1PE18-0AL1
6SL3210-
1PE21-1AL0