ROTARY INDEXING TABLE CONTROLLER
EF2...B
OPERATION / DESCRIPTION OF WEISS SOFTWARE |
8.3 Machine configuration
8.3.6 Dynamic parameters
The default dynamic parameters that were taken on during selection of the rotary indexing table can be adjusted to
meet the requirements of the customer.
Changing the dynamic parameters influences the movements of the table top and the system
behaviour of the rotary indexing table. A process value that is outside the set limits (upper limit / lower limit) is not
permitted!
For applications according to SIL2, the values for quick stop ramp and STO delay time are displayed in the Quick
stop section.
For applications according to SIL3, the minimum switching time of the safety relay are displayed additionally in the
Quick stop section.
For each possible movement of a rotary indexing table, a monitoring time is determined which is activated for this
movement after 3 repetitions. In case the cycle time changes – e.g. due to temperature influences, the activated
monitoring times can be reset. New monitoring times are determined automatically after the reset.
Consultation with WEISS GmbH becomes necessary if the monitoring time is reset so that mecha-
nical damage can be avoided.
1. Enter new process values.
2. Write configuration.
Write configuration is used to save data as current process values and simultaneously update the configura-
tion file.
3. Confirm the message with OK.