ROTARY INDEXING TABLE CONTROLLER EF2...B
COMMUNICATION WITH A HIGHER-LEVEL CONTROLLER |
10.2 Profinet IO RT
Rules for assigning names:
•
Only lowercase letters
•
Letters a-z and numbers 0-9 are permitted
•
Special characters are not allowed: !"§$%&/()=?`*'_:;#+<>|~[]{}
•
Spaces are not allowed either
•
The name can have a maximum total length of 240 characters
•
Reserved names which cannot be used:
"port-xyz" or "port-xyz-abcde…"
•
The engineering system replaces invalid characters with an "x".
•
The checkmark for "Assign IP address via controller" depends on the settings of the PROFINET configuration of
the EF2.
•
By double-clicking slot 2.1000 or 2.1001, the start address proposed by HW Config can be reassigned to the
desired address.