![WEISS 3RT2017-1BB42 Manual Download Page 140](http://html.mh-extra.com/html/weiss/3rt2017-1bb42/3rt2017-1bb42_manual_953402140.webp)
Manual R06-2016
140 / 172
ROTARY INDEXING TABLE CONTROLLER EF2...B
DIAGNOSTICS |
11.2 Error and state indicators
11.2 Error and state indicators
The LED displays are located next to the CompactFlash card plug-in slot on the SIMOTION D410-2.
The following table describes the LEDs and their meanings.
For information about diagnostics using LED displays, refer to the
SIMOTION D410-2
Commissioning and
Hardware Installation Manual, Section "Diagnostics using LED displays".
LED display
LED
Description
RDY
Status indicator of the SINAMICS Inte-
grated
RUN/STOP
SIMOTION D410-2 operating states
OUT > 5V/SY
Encoder current supply > 5 V (TTL/
HTL)
Synchronization status (SY) of the
onboard PROFINET IO interface
(X150)
SF/BF
Group error / bus error
LED status
LED
Colour
Description
RDY
orange
System startup
Drive not ready for operation
Flashing orange 2.0 Hz
Switching on/off is necessary follo-
wing the internal firmware update
green
Drive ready for operation
RUN/STOP
orange
STOP
green
RUN
OUT > 5V/SY
-
Not relevant for EF2
SF/BF
Continuous red light
Error
Flashing red 0.5 Hz
IT license missing
Flashing red 2.0 Hz
Bus error