ROTARY INDEXING TABLE CONTROLLER
EF2...B
DIAGNOSTICS |
11.3 Error messages
16
Error
4
8
The selected mode requires an already optimised
quick stop ramp.
The measurement of the
optimal quick stop ramp has
to be carried out in
advance.
9
The brake test or quick stop test mode is selected
even though no motor encoder is configured or the
service function is not enabled.
Configure the motor enco-
der or enable the service
function in the configura-
tion wizard. Functionality
only for WEISS Service
10
When executing the service function brake test or
quick stop test, the motor encoder provides a speed
below the standstill threshold during the rotating
movement of the rotary indexing table.
Check the installation of the
motor encoder. Check elec-
trical connection of the
motor encoder.
11
The sensor is approached during the stopping within
the cycle.
Check loading. During
brake test: Check function
and connection of the motor
holding brake.
12
During execution of the quick stop service function,
there is a drop below the standstill threshold of the
motor encoder before ending the stopping procedure.
Check the installation of the
motor encoder. Check elec-
trical connection of the
motor encoder.
17
Note
-1
Configuration data, rotary
indexing table are limited
The configuration data is
checked by the software
for plausibility and, if
necessary, adjusted auto-
matically.
None
18
Note
-1
Error in Ethernet configu-
ration
The configuring is rejec-
ted and the previous con-
figuring remains active.
The configuration of the
Ethernet interface cannot
be set.
Check validity of the IP
address and of the subnet
mask
Check gateway
The configuration must not
be within the subnet of the
Profinet interface. Set the
default IP address via the
input for selecting the
default IP configuration.
19
Error
2
Error reading out the drive
parameters
Error ID: (x)
The required drive para-
meters cannot be read.
Switch controller on and off
Contact WEISS GmbH
20
Error
2
Ethernet configuration
cannot be set when star-
ting the controller.
Error ID: (x)
The configuration of the
Ethernet interface cannot
be set.
Check validity of the IP
address and of the subnet
mask
Check gateway
The configuration must not
be within the subnet of the
Profinet interface. Set the
default IP address via the
input for selecting the
default IP configuration.
Event
number
Category
Reaction Event text
Cause
Remedy