![WEISS 3RT2017-1BB42 Manual Download Page 144](http://html.mh-extra.com/html/weiss/3rt2017-1bb42/3rt2017-1bb42_manual_953402144.webp)
Manual R06-2016
144 / 172
ROTARY INDEXING TABLE CONTROLLER EF2...B
DIAGNOSTICS |
11.3 Error messages
21
Error
2
Profibus configuration
cannot be set when star-
ting the controller.
Error ID: (x)
The configuration of the
Profibus interface cannot
be set.
Contact WEISS GmbH
22
Error
2
Profinet IP configuration
cannot be set when star-
ting the controller.
Error ID: (x)
The IP configuration of the
Profinet interface cannot
be set.
Check validity of the IP
address and of the subnet
mask
The configuration must not
be within the subnet of the
Ethernet interface.
23
Error
2
The Profinet device name
cannot be set when star-
ting the controller.
Error ID: (x)
The device name of the
Profinet interface cannot
be set.
Check the validity of the
device name.
24
Error
2
Timeout when booting the
controller internal drive
system
Error ID: (x)
Parts of the controller
were not able to finish
startup on time.
Switch controller on and off
Contact WEISS GmbH
25
Warning
1
The maximum permissi-
ble number of switching
cycles of the motor con-
tactor will soon be rea-
ched.
Please exchange the
motor contactor
The motor contactor is
only allowed to perform a
certain number of cycles in
order to maintain the
safety function.
Replace the motor contac-
tor and reset the counter.
26
Warning
1
The number of rotary
indexing table cycles for a
service interval has been
reached.
Please carry out mainte-
nance according to the
maintenance schedule.
The service interval must
be carried out.
Carry out service interval
27
Error
4
Optimization of stop delay
time: position overrun
Reduce stop ramp time
parameter set 1 and
repeat measurement
The sensor was overrun
during optimization of stop
delay time.
Reduce stop ramp time
parameter set 1 and repeat
measurement
28
Error
4
Error during optimization
of stop delay time
Reduce start/stop ramp
time parameter set 1 and
repeat measurement
It is not possible to deter-
mine a optimized stop
delay time.
Reduce start/stop ramp
time parameter set 1 and
repeat measurement
29
Error
2
Invalid CF card serial
number
The CF card does not con-
tain a valid serial number.
Contact WEISS GmbH
30
Note
-1
Operation license is not
available. Please validate
the license of the control-
ler and carry out a restart.
The license for operating
the rotary indexing table is
not available.
Follow up on the validation
the operational license via
the WEISS user interface.
Restart the controller after
that.
31
Reserve
-
-
-
-
Event
number
Category
Reaction Event text
Cause
Remedy