Installation and operating instruction
Gas condensing unit WTC-GB 15-B Compact and WTC-GB 25-B Compact
6 Operation
83309302 1/2018-05 La
65-196
6.6.1 Info
In menu Info, the information is read only.
6.6.1.1 System
Info
System
Information
Description
1.1.1
Status
Current operating mode of system.
The operating mode is determined from the operating mode of the system and the
operating modes of the individual heating circuits.
Off
Standby
Summer
Automatic
1.1.2
External temperature
Current temperature at the external sensor (B1).
Show additional information:
Press dial knob.
Current
:
Current external temperature used for system frost protection.
Damped
:
Tendency of the outdoor temperature used for the summer-winter changeover.
Mixed
:
Calculated outdoor temperature (current and damped) used for the flow setpoint
temperature.
1.1.3
Heat demand
Heating
Required maximum flow setpoint temperature of all heating circuits.
1.1.4 … 1.1.27
Heat demand
Heating circuit …
Required flow setpoint temperature of the corresponding heating circuit.
1.1.28
Heat demand
DHW
Required flow setpoint temperature of the DHW circuit.