Installation and operating instruction
Gas condensing unit WTC-GB 15-B Compact and WTC-GB 25-B Compact
6 Operation
83309302 1/2018-05 La
60-196
6.5.3 Heating circuits
Heating
circuits
A separate submenu appears for each heating circuit.
Parameters Setting
Operating
mode
determines the type of operation of the heating circuit.
If functions (heating, DHW) are deactivated in menu
System operating mode
, the setting has
Standby
:
Frost protection on
Heating off
DHW off
Time program 1 … 3
:
Frost protection on
Heating on
Temperature level according to selected time program. Time programs can be set in parameter
Heating program
.
DHW on
(Factory setting:
Time program 1
)
Summer
:
Frost protection on
Heating off
DHW on
Comfort, Normal, Setback
:
Frost protection on
Heating on
Temperature level according to the operating mode set, independent of the time program.
DHW on
Heating-
programs
The heating program is used to stipulate the times of the day when comfort, normal or setback heating
is used.
Time program 1 … 3
The preset time programs can be customised, factory setting see [ch. 12.8].
Changing a time program:
Select time program using the knob and confirm.
Time bars are displayed.
Select week day(s) using the knob and confirm.
Time program can be edited.
The temperature of the level can be set using parameter
Room setpoint temperature
.
Set time program required in parameter
Operating mode
.
Party/
Heating pause
The temperature level of the heating program can be temporarily changed (maximum 23:45 hours).
After this time the current heating program will be reactivated.
Select
Function
and set
Party/Heating pause
.
Set level required in
Room setpoint temperature
.
Enter
Start
and
End
.
If the parameter is set to
Off
, the current heating program is activated.
(1
Factory setting and setting range depending on the heating circuit type set [ch. 12.7].