Installation and operating instruction
Gas condensing unit WTC-GB 15-B Compact and WTC-GB 25-B Compact
6 Operation
83309302 1/2018-05 La
62-196
6.5.4 Domestic hot water
Domestic hot
water
Parameters Setting
DHW setpoint
temperature
DHW temperature for normal and setback operation.
Normal
(factory setting:
50 °C
)
Setback
(factory setting:
40 °C
)
Normal and setback operation can be assigned to specific times of the day using the DHW program.
DHW
Push
DHW Push is used to cover increased hot water demand, e. g. during setback operation.
The DHW tank is heated once to the DHW setpoint temperature set for normal operation.
DHW
program
The DHW program is used to stipulate the times of the day when the DHW tank is heated to normal
temperature or setback temperature, factory setting see [ch. 12.8].
Change a time program:
Select week day(s) using the knob and confirm.
Time program can be edited.
Circulation
program
The circulation program is used to stipulate the time of day when the circulation pump is switched on,
factory setting see [ch. 12.8].
Change a time program:
Select week day(s) using the knob and confirm.
Time program can be edited.
DHW
operating
mode
Deactivate DHW preparation.
On
(factory setting):
DHW preparation activated.
Off
:
DHW preparation deactivated.
6.5.5 Statistic
Statistic
In the
Statistic
menu, daily, monthly and annual values relating to the energy
generated are displayed.
Information Description
Energy
WTC
total
Total amount of heat generated by the condensing unit.