Installation and operating instruction
Gas condensing unit WTC-GB 15-B Compact and WTC-GB 25-B Compact
5 Installation
83309302 1/2018-05 La
42-196
Connecting the condensing unit to the fresh water storage tank hydraulically
Fit inlet and outlet tap
2
.
Insert seals into ball valves and connect heating circuit to WTC, if necessary
loosen nuts
3
to compensate for tension with the help of the slotted holes.
Insert blue Gasfalit seal into the gas isolating valve and connect to the WTC, if
necessary loosen nut
3
to compensate for tension with the help of the slot.
Cut condensate hose and drain hose to length and insert into the siphon.
When tightening the nuts on the connection pipes of the WTC
1
counter-hold
with an open-ended wrench.
1
2
1
3
Observe the flow direction when mounting the non-return valve (only for WAS 100)
Insert seals into connection pipe and non-return valve (only for WAS 100)
1
and connect storage tank flow to WTC.
Insert seals into connection pipe and connect storage tank return to WTC.
When tightening the nuts on the connection pipes of the WTC
2
counter-hold
with an open-ended wrench.
1
2
2
WAS 100
WAS ... Power