  Value Range: 10 digits (any of 1, 2 ,3, 4, 5, 6, 7, 8, 9, 0) 

  Factory Setting: Same as number on WebbPhone label 

  Description: A unique serial number is assigned to each WebbPhone and is located 

on a small white label attached to the unit. This setting is programmed into the unit at 

the factory and does not need to be changed. 

4.5.15  OPERATING STATUS 

 

Command #: 

17

 

Voice Prompt: 

“BATTERY”

 

Value Range: 

0

 

 

6 (cannot be set)

 

Description: 

Indicates  battery,  phone  line  and  AC  power  status.  You

 

may  check  by 

pressing START, 17, REPLAY. Press EXIT when done. Or you may check by calling in 

from a Rescue Station or an off-site telephone.

0 = No battery / faulty battery. 
1 = Completely discharged. 
2 = Low. 
3 = Good. 
4 = Full charge. 
5 = No telephone line detected. 
6 = No AC power detected. 

Note: The battery strength value will play first. The unit will then play the codes for phone line and 
AC power only if a problem is detected. The status of the battery will refresh every 5 minutes.  
Note: The battery is a rechargeable Li-Ion battery and should have a full charge within 1 day of 
the WebbPhone being connected to AC power. Even if the battery indicates a full charge, it should 
be replaced every 2 years. 

4.5.16  LANGUAGE 

  Command #: 18 

  Voice Prompt: “LANGUAGE” 

  Value Range: 0 = English, 1 = French, 2 = English / French, 3 = French / English, 4 = 

English / Spanish 

  Factory Setting: 0 

  Description: The WebbPhone has built-in voice prompts to make it easier to program 

the  device  and  to  assist  both  the  passengers  and  monitoring  station  when  an 

emergency call is in progress. If the WebbPhone is set to either English (0) or French 

(1), voice prompts heard by the passenger, programmer and monitoring station will 

be played in the language chosen. With the settings English / French (2) or French / 

English (3), voice prompts for both passenger and monitoring station will be heard in 

the language sequence chosen. The programmer will be given the option to choose 

which  language they  wish  to  hear  the  programming  prompts in.  With  the  English  / 

Spanish  setting  (4),  all  operating  status  information  heard  by  passengers  will  be 

played in English followed by Spanish. Programmers and monitoring personnel will 

hear messages in English. 

4.5.17  FIRMWARE VERSION NUMBER 

  Command #: 19 

  Voice Prompt: <Firmware Version Number> 

  Value Range: N/A 

  Factory Setting: <Firmware Version Number> 

  Description: This option can only be replayed, not programmed. When “1, 9, REPLAY” 

is entered, the WebbPhone audibly announces the firmware version number. 

Summary of Contents for MWP-302

Page 1: ...MWP 302 USER MANUAL RAFAEL CONVERGENT ROBOTIC TECHNOLOGIES Company address...

Page 2: ...HIGH RISE APPLICATION GREATER THAN 6 STOREYS 4 4 PROGRAMMING 5 4 1 GENERAL 5 4 2 THE KEYPAD 5 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD 7 4 4 REPLAY 8 4 5 PROGRAMMING ROUTINES 8 4 6 REMOTE PROGRAMMI...

Page 3: ...will begin flashing to alert them that their call has been connected and they can be heard It is also possible to call into any WebbPhone Phones on the same telephone line need to be programmed with a...

Page 4: ...fully programmed to specific site equipment and customer requirements NOTES A maximum of 6 WebbPhones may be connected to a single phone line A touch tone analog telephone line is required WebbPhones...

Page 5: ...will request the other users to hang up their phone call 3 1 2 CALLING IN The calling party dials the telephone number associated with the telephone line connected to the WebbPhone If the line is not...

Page 6: ...ming remotely The WebbPhone should have its transformer connected to a 120V 60 Hz AC power source in order to be programmed Its backup battery may also be used for programming if AC power is temporari...

Page 7: ...mber 0 25 digits Blank 2 Secondary Phone Number 0 25 digits Blank 3 Auto Answer 0 Off 1 1 On w ring 2 On w no ring 4 Location Announcement 15 seconds max Blank 5 Access Code 5 digits 12345 6 Station N...

Page 8: ...26 Reset IP 1 Reset N A Speaker Volume 1 Lowest 3 No need to press ENTER 6 Highest Mic Volume 1 Lowest 3 No need to press ENTER 6 Highest 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD The WebbPhone shou...

Page 9: ...all of the dialing digits followed by the ENTER key The WebbPhone will audibly announce INPUT ACCEPTED YOU ENTERED followed by all of the digits entered The WebbPhone is back in main programming mode...

Page 10: ...pause Factory Setting Blank Description If a secondary phone number is entered and the WebbPhone is unsuccessful in reaching the primary phone number the unit will switch over and dial the secondary...

Page 11: ...hecked or reset on the WebbPhone 4 5 6 STATION NUMBER Analog only Command 6 Voice Prompt STATION NUMBER Value Range 1 80 Factory Setting 1 Description A unique number must be assigned to each WebbPhon...

Page 12: ...Description This is the length of time that the WebbPhone will permit a caller to be put on hold before it hangs up and dials the next number in its sequence The timer is cancelled as soon as the oper...

Page 13: ...diagnostics done in a voice format When Voice Alert is activated the elevator telephone will provide a voice announcement over its internal speaker if it detects loss of the phone line loss of AC pow...

Page 14: ...e The battery is a rechargeable Li Ion battery and should have a full charge within 1 day of the WebbPhone being connected to AC power Even if the battery indicates a full charge it should be replaced...

Page 15: ...ss Code EXIT 9 ENTER REPLAY Table 4 Remote Programming To program remotely 1 From any phone call the telephone number of the line connected to the WebbPhone Once you hear the voice prompt enter the se...

Page 16: ...input 12V DC 1A output Maximum number of units 6 sharing the same phone line On hook Phone Line Voltage 24V 55V nominal 48V DC Off hook Phone Line Voltage 3V 10V nominal 6V DC On hook Power Required 0...

Page 17: ...aker and Microphone holes align between the MWP 302 and the COP 8 WARRANTY AND RETURNS Webb Electronics Inc warrants parts and labor on all equipment of its own manufacture for a period of 24 months f...

Page 18: ...o remove the equipment from the network until the problem is resolved This equipment cannot be used on public coin service provided by the telephone company Connection to party lines is subject to sta...