background image

4427 Dawson Street 

Burnaby, B.C., Canada V5C 4B8 

Office: 604.502-9007 

Fax: 604.502-9044 

Web: 

www.webbelectronicsinc.com

 

 
 

 

 
Document Name:  MWP-302 User Manual 

1 0   o f   1 7  

CONFIDENTIAL, Copyright © 2018 

This document is proprietary to Webb Electronics Inc. It may not be copied or otherwise 
distributed without the express consent of Webb Electronics Inc.

 

Note: To alert the programmer when to start recording the message, a ½ second tone will sound 
after the location announcement voice prompt. 

Note: If the recording exceeds 15 seconds, a beep tone will sound and only the first 15 seconds 
will be recorded. 

Note:  The  location  message may  be  replayed by  the  monitoring station at  any  time  during the 
conversation by pressing the 

#

2 key on a touch-tone phone. 

4.5.5  ACCESS CODE 

  Command #: 5

  Voice Prompt: “ACCESS CODE”

  Value Range: 5 digits (any of 1, 2 ,3, 4, 5, 6, 7, 8, 9, 0)

  Factory Setting: 12345

  Description:  To  program  the  WebbPhone  from  a  remote location, the  caller will be 

required to enter a 5-digit access code. Changing the access code to a unique number 

will prevent others from calling in and modifying the settings. 

Note: Make sure you record your access code. Without it, you will not be able to remotely access 
the phone programming. 

Note: If you do forget your access code, it can be checked or reset on the WebbPhone. 

4.5.6  STATION NUMBER (Analog-only) 

  Command #: 6

  Voice Prompt: “STATION NUMBER”

  Value Range: 1 – 80

  Factory Setting: 1

  Description:  A  unique  number  must  be  assigned  to  each  WebbPhone  without  a 

Rescue Station to allow off-site location call-ins to connect to the unit. The number is 

ignored if the phone is attached to a LS-250 Rescue Station. 

Note: In order for the voice prompting feature to work when calling into the WebbPhones without 
a Rescue Station, one cab must be assigned as Station #1. 

 

4.5.7  TALK TIME 

  Command #: 7

  Voice Prompt: “TALK TIME”



Value Range: 1 – 99 minutes

 (

Factory Setting: 5 minutes) 

 

  Description: Talk time is the length of time that the WebbPhone will stay on when a 

call is made, beginning as soon as the call is answered. The unit will automatically 

shut off after the programmed time. 

Note: Near the end of the programmed talk time period, a voice will prompt the operator to press 
the 1 key to extend the conversation. Pressing 1 (after the prompt has played) will reset the timer 
and the talk time cycle will begin again. 

Note:  When  the conversation  has  finished,  the  operator  may  also  shut  off  the  WebbPhone  by 
pressing * #. 

Note: If Voice-Alert™ is activated, the recommend Talk Time would be a minimum of 10 minutes 
as this controls the announcement frequency. (See discussion of Function 12 for more details). 

4.5.8  PRIMARY RING TRANSFER COUNT 

  Command #: 8

  Voice Prompt: “PRIMARY RING TRANSFER COUNT”

  Value Range: 1 – 20 rings

  Factory Setting: 5

Summary of Contents for MWP-302

Page 1: ...MWP 302 USER MANUAL RAFAEL CONVERGENT ROBOTIC TECHNOLOGIES Company address...

Page 2: ...HIGH RISE APPLICATION GREATER THAN 6 STOREYS 4 4 PROGRAMMING 5 4 1 GENERAL 5 4 2 THE KEYPAD 5 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD 7 4 4 REPLAY 8 4 5 PROGRAMMING ROUTINES 8 4 6 REMOTE PROGRAMMI...

Page 3: ...will begin flashing to alert them that their call has been connected and they can be heard It is also possible to call into any WebbPhone Phones on the same telephone line need to be programmed with a...

Page 4: ...fully programmed to specific site equipment and customer requirements NOTES A maximum of 6 WebbPhones may be connected to a single phone line A touch tone analog telephone line is required WebbPhones...

Page 5: ...will request the other users to hang up their phone call 3 1 2 CALLING IN The calling party dials the telephone number associated with the telephone line connected to the WebbPhone If the line is not...

Page 6: ...ming remotely The WebbPhone should have its transformer connected to a 120V 60 Hz AC power source in order to be programmed Its backup battery may also be used for programming if AC power is temporari...

Page 7: ...mber 0 25 digits Blank 2 Secondary Phone Number 0 25 digits Blank 3 Auto Answer 0 Off 1 1 On w ring 2 On w no ring 4 Location Announcement 15 seconds max Blank 5 Access Code 5 digits 12345 6 Station N...

Page 8: ...26 Reset IP 1 Reset N A Speaker Volume 1 Lowest 3 No need to press ENTER 6 Highest Mic Volume 1 Lowest 3 No need to press ENTER 6 Highest 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD The WebbPhone shou...

Page 9: ...all of the dialing digits followed by the ENTER key The WebbPhone will audibly announce INPUT ACCEPTED YOU ENTERED followed by all of the digits entered The WebbPhone is back in main programming mode...

Page 10: ...pause Factory Setting Blank Description If a secondary phone number is entered and the WebbPhone is unsuccessful in reaching the primary phone number the unit will switch over and dial the secondary...

Page 11: ...hecked or reset on the WebbPhone 4 5 6 STATION NUMBER Analog only Command 6 Voice Prompt STATION NUMBER Value Range 1 80 Factory Setting 1 Description A unique number must be assigned to each WebbPhon...

Page 12: ...Description This is the length of time that the WebbPhone will permit a caller to be put on hold before it hangs up and dials the next number in its sequence The timer is cancelled as soon as the oper...

Page 13: ...diagnostics done in a voice format When Voice Alert is activated the elevator telephone will provide a voice announcement over its internal speaker if it detects loss of the phone line loss of AC pow...

Page 14: ...e The battery is a rechargeable Li Ion battery and should have a full charge within 1 day of the WebbPhone being connected to AC power Even if the battery indicates a full charge it should be replaced...

Page 15: ...ss Code EXIT 9 ENTER REPLAY Table 4 Remote Programming To program remotely 1 From any phone call the telephone number of the line connected to the WebbPhone Once you hear the voice prompt enter the se...

Page 16: ...input 12V DC 1A output Maximum number of units 6 sharing the same phone line On hook Phone Line Voltage 24V 55V nominal 48V DC Off hook Phone Line Voltage 3V 10V nominal 6V DC On hook Power Required 0...

Page 17: ...aker and Microphone holes align between the MWP 302 and the COP 8 WARRANTY AND RETURNS Webb Electronics Inc warrants parts and labor on all equipment of its own manufacture for a period of 24 months f...

Page 18: ...o remove the equipment from the network until the problem is resolved This equipment cannot be used on public coin service provided by the telephone company Connection to party lines is subject to sta...