background image

4427 Dawson Street 

Burnaby, B.C., Canada V5C 4B8 

Office: 604.502-9007 

Fax: 604.502-9044 

Web: 

www.webbelectronicsinc.com

 

 
 

 

 
Document Name:  MWP-302 User Manual 

1 7   o f   1 7  

CONFIDENTIAL, Copyright © 2018 

This document is proprietary to Webb Electronics Inc. It may not be copied or otherwise 
distributed without the express consent of Webb Electronics Inc.

 

If this equipment causes harm to the telephone network, the telephone company will notify you in advance 
that temporary discontinuance of service may be required. If advance notice isn’t practical, the telephone 
company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint 
with the FCC if you believe it is necessary. 

 

The telephone company may make changes in its facilities, equipment, operations, or procedures that could 
affect the operation of the equipment. If this happens, the telephone company will provide advance notice 
for you to make the necessary modifications to maintain uninterrupted service. 

 

If experiencing trouble with this equipment, please contact the Technical Support Center at 
Webb Electronics Inc. for warranty and/or repair information. If the trouble is causing harm to 
the telephone network, the telephone company may request you to remove the  equipment 
from the network until the problem is resolved. 

 

This equipment cannot be used on public coin service provided by the telephone company. 

Connection  to  party  lines  is  subject  to  state  tariffs.  Contact  your  state  public  utilities 
commission for information. 

 

This equipment does not provide data operation. 

 

JACK (USOC): RJ11C 

RINGER EQUIVALENCE = 0.8 Class B 

 

 

CANADA CERTIFICATION

 

 

NOTICE: 

This product meets the applicable Innovation, Science and Economic Development Canada technical 

specifications This is confirmed by the registration number.  The  abbreviation, IC, before the registration number 
signifies that registration was performed based on a Declaration of Conformity indicating that Innovation, Science 
and Economic Development Canada (ISED) technical specifications were met. It does not imply that ISED approved 
the equipment. 

 

NOTICE

:

 

The Canadian Ringer Equivalence Number (REN) for this equipment is: 0.1. The REN assigned to each 

terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone 
interface. The termination on an interface may consist of any combination of devices subject only to the requirement 
that the sum of the Ringer Equivalence Numbers of all the devices does not exceed five. 
 
 

 

 

 

 

 

WEBB ELECTRONICS INC.

 

Canada

:  Vancouver, Toronto, Montreal 

 

Toll Free

:  1-877-731-1010

 

Fax

:  1-877-731-1028 

Technical Support

:  [email protected] 

Web Site

:  www.webbelectronicsinc.com 

 

 

 

Summary of Contents for MWP-302

Page 1: ...MWP 302 USER MANUAL RAFAEL CONVERGENT ROBOTIC TECHNOLOGIES Company address...

Page 2: ...HIGH RISE APPLICATION GREATER THAN 6 STOREYS 4 4 PROGRAMMING 5 4 1 GENERAL 5 4 2 THE KEYPAD 5 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD 7 4 4 REPLAY 8 4 5 PROGRAMMING ROUTINES 8 4 6 REMOTE PROGRAMMI...

Page 3: ...will begin flashing to alert them that their call has been connected and they can be heard It is also possible to call into any WebbPhone Phones on the same telephone line need to be programmed with a...

Page 4: ...fully programmed to specific site equipment and customer requirements NOTES A maximum of 6 WebbPhones may be connected to a single phone line A touch tone analog telephone line is required WebbPhones...

Page 5: ...will request the other users to hang up their phone call 3 1 2 CALLING IN The calling party dials the telephone number associated with the telephone line connected to the WebbPhone If the line is not...

Page 6: ...ming remotely The WebbPhone should have its transformer connected to a 120V 60 Hz AC power source in order to be programmed Its backup battery may also be used for programming if AC power is temporari...

Page 7: ...mber 0 25 digits Blank 2 Secondary Phone Number 0 25 digits Blank 3 Auto Answer 0 Off 1 1 On w ring 2 On w no ring 4 Location Announcement 15 seconds max Blank 5 Access Code 5 digits 12345 6 Station N...

Page 8: ...26 Reset IP 1 Reset N A Speaker Volume 1 Lowest 3 No need to press ENTER 6 Highest Mic Volume 1 Lowest 3 No need to press ENTER 6 Highest 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD The WebbPhone shou...

Page 9: ...all of the dialing digits followed by the ENTER key The WebbPhone will audibly announce INPUT ACCEPTED YOU ENTERED followed by all of the digits entered The WebbPhone is back in main programming mode...

Page 10: ...pause Factory Setting Blank Description If a secondary phone number is entered and the WebbPhone is unsuccessful in reaching the primary phone number the unit will switch over and dial the secondary...

Page 11: ...hecked or reset on the WebbPhone 4 5 6 STATION NUMBER Analog only Command 6 Voice Prompt STATION NUMBER Value Range 1 80 Factory Setting 1 Description A unique number must be assigned to each WebbPhon...

Page 12: ...Description This is the length of time that the WebbPhone will permit a caller to be put on hold before it hangs up and dials the next number in its sequence The timer is cancelled as soon as the oper...

Page 13: ...diagnostics done in a voice format When Voice Alert is activated the elevator telephone will provide a voice announcement over its internal speaker if it detects loss of the phone line loss of AC pow...

Page 14: ...e The battery is a rechargeable Li Ion battery and should have a full charge within 1 day of the WebbPhone being connected to AC power Even if the battery indicates a full charge it should be replaced...

Page 15: ...ss Code EXIT 9 ENTER REPLAY Table 4 Remote Programming To program remotely 1 From any phone call the telephone number of the line connected to the WebbPhone Once you hear the voice prompt enter the se...

Page 16: ...input 12V DC 1A output Maximum number of units 6 sharing the same phone line On hook Phone Line Voltage 24V 55V nominal 48V DC Off hook Phone Line Voltage 3V 10V nominal 6V DC On hook Power Required 0...

Page 17: ...aker and Microphone holes align between the MWP 302 and the COP 8 WARRANTY AND RETURNS Webb Electronics Inc warrants parts and labor on all equipment of its own manufacture for a period of 24 months f...

Page 18: ...o remove the equipment from the network until the problem is resolved This equipment cannot be used on public coin service provided by the telephone company Connection to party lines is subject to sta...

Reviews: