background image

4427 Dawson Street 

Burnaby, B.C., Canada V5C 4B8 

Office: 604.502-9007 

Fax: 604.502-9044 

Web: 

www.webbelectronicsinc.com

 

 
 

 

 
Document Name:  MWP-302 User Manual 

1 1   o f   1 7  

CONFIDENTIAL, Copyright © 2018 

This document is proprietary to Webb Electronics Inc. It may not be copied or otherwise 
distributed without the express consent of Webb Electronics Inc.

 

  Description: This is the number of rings that the WebbPhone will count after dialing 

the primary phone number before concluding that there has been no answer. After 

the last ring, the unit will hang up and perform the appropriate action. This would either 

be  to  call  the  next  dialing  destination  or  to  hang  up  if  3  calling  cycles  have  been 

completed. 

4.5.9  SECONDARY RING TRANSFER COUNT 

 

Command #: 

9

 

Voice Prompt: 

“SECONDARY RING TRANSFER COUNT”

 

Value Range: 

1

 

 

20 rings

 

Factory Setting: 

5

  Description:  This  function  serves  the  same  purpose  as  Function  8,  except  that  it 

applies to the number of rings counted after dialing the secondary phone number. 

4.5.10  OPERATOR WAIT TIME 

 

Command #: 

10

 

Voice Prompt: 

“OPERATOR WAIT TIME”

 

Value Range: 

20

 

 

200 seconds

 

Factory Setting: 

90 seconds

  Description: This is the length of time that the WebbPhone will permit a caller to be 

put on hold before it hangs up and dials the next number in its sequence. The timer 

is cancelled as soon as the operator presses the 1 key to speak to the caller or the 2 

key to listen to the location announcement. 

Note: This value is unused if Operator Prompt is OFF (see following). 

4.5.11  OPERATOR PROMPT 

 

Command #: 

11

 

Voice Prompt: 

“OPERATOR PROMPT”

 

Value Range: 

0 = OFF, 1 = ON

 

Factory Setting: 

1

  Description: When ON, a prompt message will repeat itself until either the operator 

presses  the  appropriate  key,  or  the  Operator  Wait  Time  period  expires.  The 

passenger  will  hear  a  “CALL  IN  PROGRESS”  message  until  the  operator  comes 

online. When OFF, the WebbPhone will be in two-way communication mode as soon 

as a voice is heard or ringing stops. The chart below shows how the various settings 

affect the flashing LED and the message played. 

 

 

Activate 

 

 

Location 

 

 

 

 

 

When Alert 

 

 

   

     

   

 

 

Operator 

 

 

 

 

Message Played 

 

 

LED Begins 

 

 

 

 

Announcement 

 

 

 

 

 

 

Prompt 

 

 

 

   

 

 

Flashing 

 

 

     

     

   

 

 

0 (OFF) 

Blank or Recorded 

 

No message played 

As soon as call 

 

 

answered 

 

 

 

   

 

   

 

   

     

     

 

 

1 (ON) 

Blank 

 

“Incoming Webb emergency 

After operator 

 

 

call. Push 1 to speak to caller.” 

presses ‘1’ 

 

 

 

   

 

 

   

     

     

   

 

   

     

   

“Incoming Webb emergency 

After operator 

 

1 (ON) 

Recorded 

 

call. Push 1 to speak to caller, 

 

 

presses ‘1’ 

 

 

 

   

 

 

or 2 to hear the location.” 

 

 

 

   

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                                                                       Table 3 – Operator Prompt 

 

Summary of Contents for MWP-302

Page 1: ...MWP 302 USER MANUAL RAFAEL CONVERGENT ROBOTIC TECHNOLOGIES Company address...

Page 2: ...HIGH RISE APPLICATION GREATER THAN 6 STOREYS 4 4 PROGRAMMING 5 4 1 GENERAL 5 4 2 THE KEYPAD 5 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD 7 4 4 REPLAY 8 4 5 PROGRAMMING ROUTINES 8 4 6 REMOTE PROGRAMMI...

Page 3: ...will begin flashing to alert them that their call has been connected and they can be heard It is also possible to call into any WebbPhone Phones on the same telephone line need to be programmed with a...

Page 4: ...fully programmed to specific site equipment and customer requirements NOTES A maximum of 6 WebbPhones may be connected to a single phone line A touch tone analog telephone line is required WebbPhones...

Page 5: ...will request the other users to hang up their phone call 3 1 2 CALLING IN The calling party dials the telephone number associated with the telephone line connected to the WebbPhone If the line is not...

Page 6: ...ming remotely The WebbPhone should have its transformer connected to a 120V 60 Hz AC power source in order to be programmed Its backup battery may also be used for programming if AC power is temporari...

Page 7: ...mber 0 25 digits Blank 2 Secondary Phone Number 0 25 digits Blank 3 Auto Answer 0 Off 1 1 On w ring 2 On w no ring 4 Location Announcement 15 seconds max Blank 5 Access Code 5 digits 12345 6 Station N...

Page 8: ...26 Reset IP 1 Reset N A Speaker Volume 1 Lowest 3 No need to press ENTER 6 Highest Mic Volume 1 Lowest 3 No need to press ENTER 6 Highest 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD The WebbPhone shou...

Page 9: ...all of the dialing digits followed by the ENTER key The WebbPhone will audibly announce INPUT ACCEPTED YOU ENTERED followed by all of the digits entered The WebbPhone is back in main programming mode...

Page 10: ...pause Factory Setting Blank Description If a secondary phone number is entered and the WebbPhone is unsuccessful in reaching the primary phone number the unit will switch over and dial the secondary...

Page 11: ...hecked or reset on the WebbPhone 4 5 6 STATION NUMBER Analog only Command 6 Voice Prompt STATION NUMBER Value Range 1 80 Factory Setting 1 Description A unique number must be assigned to each WebbPhon...

Page 12: ...Description This is the length of time that the WebbPhone will permit a caller to be put on hold before it hangs up and dials the next number in its sequence The timer is cancelled as soon as the oper...

Page 13: ...diagnostics done in a voice format When Voice Alert is activated the elevator telephone will provide a voice announcement over its internal speaker if it detects loss of the phone line loss of AC pow...

Page 14: ...e The battery is a rechargeable Li Ion battery and should have a full charge within 1 day of the WebbPhone being connected to AC power Even if the battery indicates a full charge it should be replaced...

Page 15: ...ss Code EXIT 9 ENTER REPLAY Table 4 Remote Programming To program remotely 1 From any phone call the telephone number of the line connected to the WebbPhone Once you hear the voice prompt enter the se...

Page 16: ...input 12V DC 1A output Maximum number of units 6 sharing the same phone line On hook Phone Line Voltage 24V 55V nominal 48V DC Off hook Phone Line Voltage 3V 10V nominal 6V DC On hook Power Required 0...

Page 17: ...aker and Microphone holes align between the MWP 302 and the COP 8 WARRANTY AND RETURNS Webb Electronics Inc warrants parts and labor on all equipment of its own manufacture for a period of 24 months f...

Page 18: ...o remove the equipment from the network until the problem is resolved This equipment cannot be used on public coin service provided by the telephone company Connection to party lines is subject to sta...