background image

4427 Dawson Street 

Burnaby, B.C., Canada V5C 4B8 

Office: 604.502-9007 

Fax: 604.502-9044 

Web: 

www.webbelectronicsinc.com

 

 
 

 

 
Document Name:  MWP-302 User Manual 

2   o f   1 7  

CONFIDENTIAL, Copyright © 2018 

This document is proprietary to Webb Electronics Inc. It may not be copied or otherwise 
distributed without the express consent of Webb Electronics Inc.

 

 

                                              TABLE 1 – MODEL NUMBERS

 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1  INTRODUCTION 

Thank you for purchasing this Webb Electronics product. It has been designed for easy installation 
and will provide many years of reliable service. 

 

The WebbPhone is AC powered with an internal rechargeable backup battery, is ADA compliant, and 
connects  to  a  regular  telephone  line.  Pressing  the  call  button  initiates  a  call  to  a  primary  pre-
programmed number. Should the primary number be busy or go unanswered, the WebbPhone will call 
a  secondary  number  for  assistance.  The  WebbPhone  will  alternate  calls  between  the  primary  and 
secondary monitoring numbers until the call has been answered. 

 

When the call is answered, the phone will voice prompt the instructions on how to communicate with 
the passenger and how to determine the location of the passenger. For callers with a hearing disability, 
a

n

 LED will begin flashing to alert them that their call has been connected and they can be heard. 

 

It  is  also  possible  to  call  into  any  WebbPhone.  Phones  on  the  same  telephone  line  need  to  be 
programmed with a unique address – 1 through 6. When an incoming call is received, all phones answer 
simultaneously. The phone programmed with address 1 plays the audible prompt “ENTER THE CAB 
NUMBER YOU WISH TO SPEAK TO, THEN PRESS THE * KEY”. All phones except the one selected 
will hang up. 

 

Part Name 

Description 

Language 

BXR-302B 

Webb Emergency Phone, Box Style, Black Powder Coat 

Bilingual 

BXR-302E 

Webb Emergency Phone, Box Style, Black Powder Coat 

English 

BXS-302B 

Webb Emergency Phone, Box Style, Stainless Steel 

Bilingual 

BXS-302E 

Webb Emergency Phone, Box Style, Stainless Steel 

English 

FMM-302B 

Webb Emergency Phone 302, Flush mount, stainless steel, 

10"Wx13"H, Bilingual 

Bilingual 

FMM-302E 

Webb Emergency Phone 302, Flush mount, stainless steel, 

10"Wx13"H 

English 

FMS-302B 

Webb Emergency Phone 302, Flush mount, stainless steel, 

6.5"Wx10"H 

Bilingual 

FMS-302E 

Webb Emergency Phone 302, Flush mount, stainless steel, 

6.5"Wx10"H 

English 

FMC-302B 

Webb Emergency Phone 302, Flush mount, stainless steel, 

15"Wx15"H, Bilingual - Custom Cut 

Bilingual 

FMC-302E 

Webb Emergency Phone 302, Flush mount, stainless steel, 

15"Wx15"H, English - Custom Cut 

English 

MWP-302 

MWP-150 Webb Hands Free Emergency phone un-housed. 

Bilingual 

Summary of Contents for MWP-302

Page 1: ...MWP 302 USER MANUAL RAFAEL CONVERGENT ROBOTIC TECHNOLOGIES Company address...

Page 2: ...HIGH RISE APPLICATION GREATER THAN 6 STOREYS 4 4 PROGRAMMING 5 4 1 GENERAL 5 4 2 THE KEYPAD 5 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD 7 4 4 REPLAY 8 4 5 PROGRAMMING ROUTINES 8 4 6 REMOTE PROGRAMMI...

Page 3: ...will begin flashing to alert them that their call has been connected and they can be heard It is also possible to call into any WebbPhone Phones on the same telephone line need to be programmed with a...

Page 4: ...fully programmed to specific site equipment and customer requirements NOTES A maximum of 6 WebbPhones may be connected to a single phone line A touch tone analog telephone line is required WebbPhones...

Page 5: ...will request the other users to hang up their phone call 3 1 2 CALLING IN The calling party dials the telephone number associated with the telephone line connected to the WebbPhone If the line is not...

Page 6: ...ming remotely The WebbPhone should have its transformer connected to a 120V 60 Hz AC power source in order to be programmed Its backup battery may also be used for programming if AC power is temporari...

Page 7: ...mber 0 25 digits Blank 2 Secondary Phone Number 0 25 digits Blank 3 Auto Answer 0 Off 1 1 On w ring 2 On w no ring 4 Location Announcement 15 seconds max Blank 5 Access Code 5 digits 12345 6 Station N...

Page 8: ...26 Reset IP 1 Reset N A Speaker Volume 1 Lowest 3 No need to press ENTER 6 Highest Mic Volume 1 Lowest 3 No need to press ENTER 6 Highest 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD The WebbPhone shou...

Page 9: ...all of the dialing digits followed by the ENTER key The WebbPhone will audibly announce INPUT ACCEPTED YOU ENTERED followed by all of the digits entered The WebbPhone is back in main programming mode...

Page 10: ...pause Factory Setting Blank Description If a secondary phone number is entered and the WebbPhone is unsuccessful in reaching the primary phone number the unit will switch over and dial the secondary...

Page 11: ...hecked or reset on the WebbPhone 4 5 6 STATION NUMBER Analog only Command 6 Voice Prompt STATION NUMBER Value Range 1 80 Factory Setting 1 Description A unique number must be assigned to each WebbPhon...

Page 12: ...Description This is the length of time that the WebbPhone will permit a caller to be put on hold before it hangs up and dials the next number in its sequence The timer is cancelled as soon as the oper...

Page 13: ...diagnostics done in a voice format When Voice Alert is activated the elevator telephone will provide a voice announcement over its internal speaker if it detects loss of the phone line loss of AC pow...

Page 14: ...e The battery is a rechargeable Li Ion battery and should have a full charge within 1 day of the WebbPhone being connected to AC power Even if the battery indicates a full charge it should be replaced...

Page 15: ...ss Code EXIT 9 ENTER REPLAY Table 4 Remote Programming To program remotely 1 From any phone call the telephone number of the line connected to the WebbPhone Once you hear the voice prompt enter the se...

Page 16: ...input 12V DC 1A output Maximum number of units 6 sharing the same phone line On hook Phone Line Voltage 24V 55V nominal 48V DC Off hook Phone Line Voltage 3V 10V nominal 6V DC On hook Power Required 0...

Page 17: ...aker and Microphone holes align between the MWP 302 and the COP 8 WARRANTY AND RETURNS Webb Electronics Inc warrants parts and labor on all equipment of its own manufacture for a period of 24 months f...

Page 18: ...o remove the equipment from the network until the problem is resolved This equipment cannot be used on public coin service provided by the telephone company Connection to party lines is subject to sta...