Note: If a location announcement has been recorded, the operator can press 2 at any time when 
speaking to the caller and replay the location announcement. 

Important Note

:

 

Remember that by turning the Operator Prompt function off, the operator 

may  have  a  difficult  time  determining  where  the  call  is  coming  from.  Not  all  monitoring 

stations have Caller ID on their telephone and passengers cannot always identify exactly 

where they are calling from.

4.5.12  SELF-DIAGNOSTICS 

 

Command #: 

12

 

Voice Prompt: 

“AutoCheck”

 

Value Range: 

0 = OFF, 1 = [Not Used], 2 = Voice-Alert, 3 = LAS, 4 =

 

[Not Used], 5 

LAS + Voice-Alert

 

Factory Setting: 

0

  Description: Self  diagnostics are available to all Webb customers. When activated, 

the  software  within  each  hands-free  telephone  will  automatically  check  its  internal 

operation and create an alert signal if any of the following problems exist: 

Phones are not able to call out normally.

AC power has been cut off to the WebbPhones.

Backup batteries need replacing.

 

  The 

LAS

  (Lobby  Alert  System)  generates  an  audible  &  visual  alert  in  the  elevator 

lobby. The LA-LS checks the phone line to the LS250 Rescue Station 

 

 

Voice-Alert™

  is  self-diagnostics  done  in  a  voice  format.  When  Voice-Alert™  is 

activated, the elevator telephone will provide a voice announcement over its internal 

speaker if it detects loss of the phone line, loss of AC power, or a low backup battery. 

This will repeat at whatever frequency Talk Time is set to (Function 7). For passenger 

convenience, we would recommend that the cycle be set to 10 minutes or longer. The 

announcement  is  made  in  whatever  languages  the  WebbPhone  has  been  set  to 

(Function 18). 

  An  owner  considers  activating  self-diagnostics  for  safety  and  liability  reasons. 

Research indicates that approximately ½ of all calls to fix elevator telephones are a 

result of someone having been stuck and finding that the phones didn’t work. Being 

unable to  contact  help  in  an  emergency not  only  places passengers in  danger but 

also exposes the owners to a significant liability risk. Self-diagnostics helps owners 

eliminate both of these potentially serious problems. 

  The 

LAS Lobby Alert System

 verifies the operability of the telephone line from the 

cab onwards. The WebbPhone works with the LA-LS and the LS-250 Rescue Station 

to produce an alarm in the lobby. Set Functions 12 to 3 or 5 

 

Line Monitoring

 is done on the NO connector.

4.5.13  LOBBY STATION AUTO SENSE 

 

Command #: 

13

 

Voice Prompt: 

“LOBBY STATION”

 

Value Range: 

0 or 1

 

Factory Setting: 

0

  Description: If a WebbPhone is connected to the LS-250, it is guaranteed to have its 

own phone line, so it will not play a prompt. You will just hear “Connected.” In low-rise 

mode, if you have a dedicated phone line and you want to turn off the prompt, you will 

need to manually set it to “1.” 

4.5.14  SERIAL NUMBER 

  Command #: 14 

  Voice Prompt: “SERIAL NUMBER” 

Summary of Contents for MWP-302

Page 1: ...MWP 302 USER MANUAL RAFAEL CONVERGENT ROBOTIC TECHNOLOGIES Company address...

Page 2: ...HIGH RISE APPLICATION GREATER THAN 6 STOREYS 4 4 PROGRAMMING 5 4 1 GENERAL 5 4 2 THE KEYPAD 5 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD 7 4 4 REPLAY 8 4 5 PROGRAMMING ROUTINES 8 4 6 REMOTE PROGRAMMI...

Page 3: ...will begin flashing to alert them that their call has been connected and they can be heard It is also possible to call into any WebbPhone Phones on the same telephone line need to be programmed with a...

Page 4: ...fully programmed to specific site equipment and customer requirements NOTES A maximum of 6 WebbPhones may be connected to a single phone line A touch tone analog telephone line is required WebbPhones...

Page 5: ...will request the other users to hang up their phone call 3 1 2 CALLING IN The calling party dials the telephone number associated with the telephone line connected to the WebbPhone If the line is not...

Page 6: ...ming remotely The WebbPhone should have its transformer connected to a 120V 60 Hz AC power source in order to be programmed Its backup battery may also be used for programming if AC power is temporari...

Page 7: ...mber 0 25 digits Blank 2 Secondary Phone Number 0 25 digits Blank 3 Auto Answer 0 Off 1 1 On w ring 2 On w no ring 4 Location Announcement 15 seconds max Blank 5 Access Code 5 digits 12345 6 Station N...

Page 8: ...26 Reset IP 1 Reset N A Speaker Volume 1 Lowest 3 No need to press ENTER 6 Highest Mic Volume 1 Lowest 3 No need to press ENTER 6 Highest 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD The WebbPhone shou...

Page 9: ...all of the dialing digits followed by the ENTER key The WebbPhone will audibly announce INPUT ACCEPTED YOU ENTERED followed by all of the digits entered The WebbPhone is back in main programming mode...

Page 10: ...pause Factory Setting Blank Description If a secondary phone number is entered and the WebbPhone is unsuccessful in reaching the primary phone number the unit will switch over and dial the secondary...

Page 11: ...hecked or reset on the WebbPhone 4 5 6 STATION NUMBER Analog only Command 6 Voice Prompt STATION NUMBER Value Range 1 80 Factory Setting 1 Description A unique number must be assigned to each WebbPhon...

Page 12: ...Description This is the length of time that the WebbPhone will permit a caller to be put on hold before it hangs up and dials the next number in its sequence The timer is cancelled as soon as the oper...

Page 13: ...diagnostics done in a voice format When Voice Alert is activated the elevator telephone will provide a voice announcement over its internal speaker if it detects loss of the phone line loss of AC pow...

Page 14: ...e The battery is a rechargeable Li Ion battery and should have a full charge within 1 day of the WebbPhone being connected to AC power Even if the battery indicates a full charge it should be replaced...

Page 15: ...ss Code EXIT 9 ENTER REPLAY Table 4 Remote Programming To program remotely 1 From any phone call the telephone number of the line connected to the WebbPhone Once you hear the voice prompt enter the se...

Page 16: ...input 12V DC 1A output Maximum number of units 6 sharing the same phone line On hook Phone Line Voltage 24V 55V nominal 48V DC Off hook Phone Line Voltage 3V 10V nominal 6V DC On hook Power Required 0...

Page 17: ...aker and Microphone holes align between the MWP 302 and the COP 8 WARRANTY AND RETURNS Webb Electronics Inc warrants parts and labor on all equipment of its own manufacture for a period of 24 months f...

Page 18: ...o remove the equipment from the network until the problem is resolved This equipment cannot be used on public coin service provided by the telephone company Connection to party lines is subject to sta...