4427 Dawson Street
Burnaby, B.C., Canada V5C 4B8
Office: 604.502-9007
Fax: 604.502-9044
Web:
www.webbelectronicsinc.com
Document Name: MWP-302 User Manual
1 2 o f 1 7
CONFIDENTIAL, Copyright © 2018
This document is proprietary to Webb Electronics Inc. It may not be copied or otherwise
distributed without the express consent of Webb Electronics Inc.
Note: If a location announcement has been recorded, the operator can press 2 at any time when
speaking to the caller and replay the location announcement.
Important Note
:
Remember that by turning the Operator Prompt function off, the operator
may have a difficult time determining where the call is coming from. Not all monitoring
stations have Caller ID on their telephone and passengers cannot always identify exactly
where they are calling from.
4.5.12 SELF-DIAGNOSTICS
Command #:
12
Voice Prompt:
“AutoCheck”
Value Range:
0 = OFF, 1 = [Not Used], 2 = Voice-Alert, 3 = LAS, 4 =
[Not Used], 5
LAS + Voice-Alert
Factory Setting:
0
Description: Self diagnostics are available to all Webb customers. When activated,
the software within each hands-free telephone will automatically check its internal
operation and create an alert signal if any of the following problems exist:
-
Phones are not able to call out normally.
-
AC power has been cut off to the WebbPhones.
-
Backup batteries need replacing.
The
LAS
(Lobby Alert System) generates an audible & visual alert in the elevator
lobby. The LA-LS checks the phone line to the LS250 Rescue Station
Voice-Alert™
is self-diagnostics done in a voice format. When Voice-Alert™ is
activated, the elevator telephone will provide a voice announcement over its internal
speaker if it detects loss of the phone line, loss of AC power, or a low backup battery.
This will repeat at whatever frequency Talk Time is set to (Function 7). For passenger
convenience, we would recommend that the cycle be set to 10 minutes or longer. The
announcement is made in whatever languages the WebbPhone has been set to
(Function 18).
An owner considers activating self-diagnostics for safety and liability reasons.
Research indicates that approximately ½ of all calls to fix elevator telephones are a
result of someone having been stuck and finding that the phones didn’t work. Being
unable to contact help in an emergency not only places passengers in danger but
also exposes the owners to a significant liability risk. Self-diagnostics helps owners
eliminate both of these potentially serious problems.
The
LAS Lobby Alert System
verifies the operability of the telephone line from the
cab onwards. The WebbPhone works with the LA-LS and the LS-250 Rescue Station
to produce an alarm in the lobby. Set Functions 12 to 3 or 5
Line Monitoring
is done on the NO connector.
4.5.13 LOBBY STATION AUTO SENSE
Command #:
13
Voice Prompt:
“LOBBY STATION”
Value Range:
0 or 1
Factory Setting:
0
Description: If a WebbPhone is connected to the LS-250, it is guaranteed to have its
own phone line, so it will not play a prompt. You will just hear “Connected.” In low-rise
mode, if you have a dedicated phone line and you want to turn off the prompt, you will
need to manually set it to “1.”
4.5.14 SERIAL NUMBER
Command #: 14
Voice Prompt: “SERIAL NUMBER”