  Remember that if a LS-250 Rescue Station is not being used, each elevator must be programmed with its own unique 

station number (Command #6) in order for individual cabs to be called. If the outside caller, for example, presses 2* and 

station number 2 hasn’t been pre-programmed with its identification number, all of the units including station #2 will shut 

off. 

6  WEBBPHONE SPECIFICATIONS 

Elevator Wiring Requirements

 

One shielded pair communication cable. Shield should be grounded at 

controller end of traveling cable. 

 

Phone Line Requirements

 

Standard analog loop starts voice grade telephone line or PBX 

 

AC/DC Transformer (supplied)

 

120V AC, 60 Hz input 

12V DC, 1A output 

 

Maximum number of units

 

sharing the same phone line 

 

On-hook Phone Line Voltage

 

24V – 55V (nominal 48V DC) 

 

Off-hook Phone Line Voltage

 

3V – 10V (nominal 6V DC) 

 

On-hook Power Required

 

0 mA 

 

Off-hook Loop Current

 

25 mA – 35 mA (nominal 30 mA) 

 

LED

 

Operating voltage 1.7V – 2.1V 

Operating current 10 – 25 mA 

 

Microphone

 

Omnidirectional back electret condenser Frequency range 20 Hz – 20 kHz 

 

Ringing Voltage

 

40 – 130V AC 

 

Operational Loop Resistance

 

600 ohms 

 

Backup Power

 

3.7V/1000 mAh rechargeable 

Li-ion battery. 

 

Replace every 2 years or as required. 

 

Operating Range

 

0 – 60 degrees Centigrade 

 

Ringer Equivalence (REN)

 

0.8 USA / 0.22 Canada 

 

Dimensions

 

4.5” (114 mm) wide x 5.25” (133 mm) high x 1.75” (44 mm) deep with mounting 

holes to match the common stud patterns 

7  TROUBLESHOOTING 

7.1 

Voltage Reference 

On Hook Voltage: 

24V – 55V DC 

Off Hook Voltage: 

3V – 10V DC 

External Power 

12  DC (Nominal) 

Battery Voltage 

4.4V VDC 

7.2 

WebbPhone is dead. No dial tone when call button is pressed. 

  Confirm that the green power LED is on (upper left of circuit board).

  Press EXIT key (phone maybe in Programming mode).

  Check  all  terminal  connections,  especially  SPEAKER  and  CALL  –  wires  in  snug  and 

terminals screws tightened.

Summary of Contents for MWP-302

Page 1: ...MWP 302 USER MANUAL RAFAEL CONVERGENT ROBOTIC TECHNOLOGIES Company address...

Page 2: ...HIGH RISE APPLICATION GREATER THAN 6 STOREYS 4 4 PROGRAMMING 5 4 1 GENERAL 5 4 2 THE KEYPAD 5 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD 7 4 4 REPLAY 8 4 5 PROGRAMMING ROUTINES 8 4 6 REMOTE PROGRAMMI...

Page 3: ...will begin flashing to alert them that their call has been connected and they can be heard It is also possible to call into any WebbPhone Phones on the same telephone line need to be programmed with a...

Page 4: ...fully programmed to specific site equipment and customer requirements NOTES A maximum of 6 WebbPhones may be connected to a single phone line A touch tone analog telephone line is required WebbPhones...

Page 5: ...will request the other users to hang up their phone call 3 1 2 CALLING IN The calling party dials the telephone number associated with the telephone line connected to the WebbPhone If the line is not...

Page 6: ...ming remotely The WebbPhone should have its transformer connected to a 120V 60 Hz AC power source in order to be programmed Its backup battery may also be used for programming if AC power is temporari...

Page 7: ...mber 0 25 digits Blank 2 Secondary Phone Number 0 25 digits Blank 3 Auto Answer 0 Off 1 1 On w ring 2 On w no ring 4 Location Announcement 15 seconds max Blank 5 Access Code 5 digits 12345 6 Station N...

Page 8: ...26 Reset IP 1 Reset N A Speaker Volume 1 Lowest 3 No need to press ENTER 6 Highest Mic Volume 1 Lowest 3 No need to press ENTER 6 Highest 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD The WebbPhone shou...

Page 9: ...all of the dialing digits followed by the ENTER key The WebbPhone will audibly announce INPUT ACCEPTED YOU ENTERED followed by all of the digits entered The WebbPhone is back in main programming mode...

Page 10: ...pause Factory Setting Blank Description If a secondary phone number is entered and the WebbPhone is unsuccessful in reaching the primary phone number the unit will switch over and dial the secondary...

Page 11: ...hecked or reset on the WebbPhone 4 5 6 STATION NUMBER Analog only Command 6 Voice Prompt STATION NUMBER Value Range 1 80 Factory Setting 1 Description A unique number must be assigned to each WebbPhon...

Page 12: ...Description This is the length of time that the WebbPhone will permit a caller to be put on hold before it hangs up and dials the next number in its sequence The timer is cancelled as soon as the oper...

Page 13: ...diagnostics done in a voice format When Voice Alert is activated the elevator telephone will provide a voice announcement over its internal speaker if it detects loss of the phone line loss of AC pow...

Page 14: ...e The battery is a rechargeable Li Ion battery and should have a full charge within 1 day of the WebbPhone being connected to AC power Even if the battery indicates a full charge it should be replaced...

Page 15: ...ss Code EXIT 9 ENTER REPLAY Table 4 Remote Programming To program remotely 1 From any phone call the telephone number of the line connected to the WebbPhone Once you hear the voice prompt enter the se...

Page 16: ...input 12V DC 1A output Maximum number of units 6 sharing the same phone line On hook Phone Line Voltage 24V 55V nominal 48V DC Off hook Phone Line Voltage 3V 10V nominal 6V DC On hook Power Required 0...

Page 17: ...aker and Microphone holes align between the MWP 302 and the COP 8 WARRANTY AND RETURNS Webb Electronics Inc warrants parts and labor on all equipment of its own manufacture for a period of 24 months f...

Page 18: ...o remove the equipment from the network until the problem is resolved This equipment cannot be used on public coin service provided by the telephone company Connection to party lines is subject to sta...