38
Part No. 920559 Rev H
November 2008
4.7 Error Codes
Computer error codes can be displayed on the side of the dispenser where the error occurred by accessing the
sub-functions
S21.XX
for Side 1 and
S22.XX
for Side 2, where
XX
is between
01
and
50
and represents the
error/events records maintained by the computer program - with 01 being the most recent. The computer can
store up to 50 errors per side, continuing to store errors beyond the 50
th
by cycling the error buffer with new
errors inserted at the top of the buffer. When this happens, an error is deleted at the bottom of the buffer for
every new error that is inserted in the top of the buffer.
Errors are displayed in an alternating 2-page format. Information in the error pages is given below.
Page 1 Error Information
Page 2 Error Information
HH.MM
MM.DD.YY
CC.DD.NN
C
Where:
Where:
HH
= hour
MM
= month
MM
= minute
DD
= day
CC
= error code
YY
= year
DD
= Device number
C
= filling count
NN
= logical nozzle number
The complete description of the error codes is given in the 3/Vista Service manual, part number 920525.
Computer errors are read by entering the Maintenance Mode and accessing the correct statistical function and
its sub-functions. Perform the following steps using the remote control.
Bold
type denote remote control
function;
italicized
type represents dispenser response.
Accessing the error code Sub-function.
1.
Press
ENTER
PASS 1
(enter password)
2.
Press
ENTER
PASS 2
(enter password)
3.
Press
ENTER.
The unit price display will show
F
4.
Press either
UP
or
DOWN
to enter the statistics viewing mode. The unit price display
will show
S—
indicating that a number needs to be selected.
5.
Press
21
to access
S21
(error data for Side 1 or A which is the junction box side)
6.
Press
ENTER.
The unit price display will show
21.01
, the first and most recent error
data for Side 1. The data will be displayed in the 2-page format described earlier, in
an alternating sequence, at a 1 second per page rate.
7.
Pressing
NEXT
accesses
21.02
and the display shows information for the second
error logged. By pressing
NEXT
, the error buffer can be viewed completely.
8.
To exit, press
CLEAR
, then
UP
or
DOWN
. The unit price display will show
S—.
9.
Press
ENTER
three times to exit to the normal display.
Summary of Contents for Ovation
Page 1: ...INSTALLATION Ovation Dispensers OPERATION...
Page 3: ...November 2008 Part No 920559 Rev H Ovation Series Dispensers Installation Operation...
Page 4: ...November 2008 Part No 920559 Rev H...
Page 54: ...48 Part No 920559 Rev H November 2008...
Page 66: ...60 Part No 920559 Rev H November 2008...
Page 67: ...61 November 2008 Part No 920559 Rev H DISTANCE BETWEEN EYE BOLTS 33 1...
Page 68: ...62 Part No 920559 Rev H November 2008 INSTALLATION INSTRUCTION page 1 of 2 OVATION MODEL R13...
Page 69: ...63 November 2008 Part No 920559 Rev H INSTALLATION INSTRUCTION page 2 of 2 OVATION MODEL R13...
Page 70: ...64 Part No 920559 Rev H November 2008 INSTALLATION INSTRUCTION page 1 of 2 OVATION MODEL B23...
Page 71: ...65 November 2008 Part No 920559 Rev H INSTALLATION INSTRUCTION page 2 of 2 OVATION MODEL B23...
Page 74: ...68 Part No 920559 Rev H November 2008 INSTALLATION INSTRUCTION page 1 of 2 OVATION MODEL R11...
Page 75: ...69 November 2008 Part No 920559 Rev H INSTALLATION INSTRUCTION page 2 of 2 OVATION MODEL R11...
Page 76: ...70 November 2008 Part No 920559 Rev H...
Page 77: ...71 November 2008 Part No 920559 Rev H 2 7151 C TYPICAL SITE WIRING...
Page 78: ...72 Part No 920559 Rev H November 2008...
Page 80: ...74 Part No 920559 Rev H November 2008...
Page 81: ...75 November 2008 Part No 920559 Rev H APPENDIX D SITE INTERCONNECTION DIAGRAMS...
Page 82: ...76 Part No 920559 Rev H November 2008 Figure D 1 Backroom Installation Wayne Control System...
Page 84: ...78 Part No 920559 Rev H November 2008 Figure D 3 Pump Relay Installation Wiring Diagram...