37
November 2008
Part No. 920559 Rev H
4.5 Restarting After Power Failure or Shutdown
After loss of power, the display accurately displays the amount of the sale, in money and vol-
ume, for approximately 15 minutes. When power is restored, all sales information returns to
the displays. Any sales in progress will be ended; old sales should be paid and the dispenser
reauthorized if more product is to be dispensed.
If the dispenser does not operate properly when power is restored (does not deliver product, or
does not reset), record both the money and volume shown on the display (so sales can be paid
for) and perform the following:
1. Ensure all nozzles on the side are in their nozzle boots.
2. Authorize the dispenser.
3. Remove the nozzle from the nozzle boot. The dispenser should operate normally. If the dis-
penser does not resume normal operation, try cycling power as described in the next sec-
tion.
4.6 Cycling Power to Clear Faults
If a fault in the dispenser is detected by the computer, an error message will be displayed in
the sale display as described in Section 4.7.
Record the displayed error message.
It may be
possible to restart the dispenser by the following sequence:
1. Ensure all nozzles are properly seated in the nozzle boot.
2. Turn the control power circuit breaker off for approximately five seconds; the dispenser
annunciator will sound. Turn the control power circuit breaker on; the dispenser annuncia-
tor will again sound.
3. Authorize the dispenser.
4. Remove the nozzle from the nozzle boot. The dispenser should operate normally.
If it is not possible to restart the dispenser using this procedure, or if an error message contin-
ues to be displayed, consult appropriate service personnel. Be certain to give the service per-
sonnel the amount at which the dispenser stopped and the exact error message.
Summary of Contents for Ovation
Page 1: ...INSTALLATION Ovation Dispensers OPERATION...
Page 3: ...November 2008 Part No 920559 Rev H Ovation Series Dispensers Installation Operation...
Page 4: ...November 2008 Part No 920559 Rev H...
Page 54: ...48 Part No 920559 Rev H November 2008...
Page 66: ...60 Part No 920559 Rev H November 2008...
Page 67: ...61 November 2008 Part No 920559 Rev H DISTANCE BETWEEN EYE BOLTS 33 1...
Page 68: ...62 Part No 920559 Rev H November 2008 INSTALLATION INSTRUCTION page 1 of 2 OVATION MODEL R13...
Page 69: ...63 November 2008 Part No 920559 Rev H INSTALLATION INSTRUCTION page 2 of 2 OVATION MODEL R13...
Page 70: ...64 Part No 920559 Rev H November 2008 INSTALLATION INSTRUCTION page 1 of 2 OVATION MODEL B23...
Page 71: ...65 November 2008 Part No 920559 Rev H INSTALLATION INSTRUCTION page 2 of 2 OVATION MODEL B23...
Page 74: ...68 Part No 920559 Rev H November 2008 INSTALLATION INSTRUCTION page 1 of 2 OVATION MODEL R11...
Page 75: ...69 November 2008 Part No 920559 Rev H INSTALLATION INSTRUCTION page 2 of 2 OVATION MODEL R11...
Page 76: ...70 November 2008 Part No 920559 Rev H...
Page 77: ...71 November 2008 Part No 920559 Rev H 2 7151 C TYPICAL SITE WIRING...
Page 78: ...72 Part No 920559 Rev H November 2008...
Page 80: ...74 Part No 920559 Rev H November 2008...
Page 81: ...75 November 2008 Part No 920559 Rev H APPENDIX D SITE INTERCONNECTION DIAGRAMS...
Page 82: ...76 Part No 920559 Rev H November 2008 Figure D 1 Backroom Installation Wayne Control System...
Page 84: ...78 Part No 920559 Rev H November 2008 Figure D 3 Pump Relay Installation Wiring Diagram...