![Waygate Technologies Everest Mentor Visual iQ VideoProbe Operating Manual Download Page 68](http://html1.mh-extra.com/html/waygate-technologies/everest-mentor-visual-iq-videoprobe/everest-mentor-visual-iq-videoprobe_operating-manual_3913187068.webp)
68
3D Stereo Measurement Procedure, Part 2
6
– Patented Zoom Window allows for precise positioning of the active cursor. Tap the window's edges (or move the cursor with the joystick) to adjust
the active cursor position.
(Click here to learn about turning the Zoom Window on or off and other Measurement Settings).
7
– Tap the screen (or hit
) to display the second cursor. Position it as described in items 5 and 6.
8
– The active dimension appears on the display screen (tapping the number turns its box blue and allows it to be repositioned).
Note: Verify correct cursor placement and 3D data quality using the Point Cloud view.
9
– Select to Add another measurement (up to five are allowed on any display). Once more than one measurement are displayed, select Next Measurement
to change which measurement is active (or simply tap on any existing measurement cursor to make it active).
10
– Tap to access alternate rows of soft keys. Double tapping in this location hides or displays the soft keys and status bar.
11
– Select Options, then Change Tip to retain the image captured and measurement(s) performed while correcting for an incorrectly specified tip serial
number. This process allows the correct calibration data to be applied and eliminates the need to collect additional images simply because the user
initially identified the wrong tip serial number.
3D Stereo Measurement Types
Click here to learn more about each type of 3D measurement.