Pagina 6.41
where the value in the diagram indicates the medium distance for signal reception during the
exercise (± 4” inches or 10 cm).
(3)
Check that the cardio receiver has been assembled properly as described in the procedure: 7.4.
“Cardio/Hand sensor receiver disassembly”, that is in good condition, work properly and the
state of the band (ie battery).
(4)
To check for electromagnetic noise near the machine, use Test Box Excite as detailed here
below. You can use one of the following cables
ELT-16
(
0WC00518AB
),
CBQ-28
(
0WC00390AC
) or
TRM-28
(
0WC00336AC
) as connection cable.
The circuit lights the LED for each heart beat and/or disturbance received: in this way it is
possible to determine whether there is any interference, and identify its sources.
(5)
Check the battery power level, using a tester if possible. Otherwise use a receiver or another
reference machine to check the operation up to a distance of about 90 cm from the receiver.
Receiver