CARDIO WAVE EXCITE Class & Trend: Service & maintenance manual- rev.2.0
Pagina 6.39
6.15.
THE TELEMETRIC HEART RATE SIGNAL IS INCORRECT
The machine displays this error if the receiver is disturbed by sources of electromagnetic noise.
THE TELEMETRIC
HR SIGNAL IS
INCORRECT
Are the machines correctly
spaced by the required minimum
distance?
Is the receiv er correctly
positioned and are the
connecting cables properly
routed?
Are there sources of
electromagnetic noise near the
receiv er?
Reposition the machines
so they are adequately
spaced
Correct the position of the
receiv er and the routing of
the cables
Mov e the machine away
f rom the noise source or
attenuate the power of the
noise
NO
YES
NO
YES
NO
YES
4
A
Check the earth connection
of the machine
1
3
2
Continued on the following page
Summary of Contents for CLASS & TREND
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 0 ...
Page 2: ......
Page 4: ......
Page 50: ...CARDIO WAVE EXCITE Class Trend Service maintenance manual rev 2 0 Pagina 4 6 LIBYA DVB T ...
Page 52: ......
Page 213: ......