17
Rev 08
NOTE:
Do not use the following fluids:
Brake Fluid
Power steering fluid
Automatic Transmission Fluid (ATF)
Fill reservoir
•
Fill with recommended fluid or equivalent.
•
Fill the reservoir to within 1/2” from the top.
•
Fluids are available from the Waltco parts
Dept. 1-800-411-5685 www.waltco.com
Recommended Fluids
Temperature Range
Acceptable Fluids
0
°
to 120
°
F
Waltco Biodegradable
Liftlube
TM
part #85803860
Shell Tellus S2 V 32
Chevron Rando HDZ 32
-20
°
to 90
°
F
Waltco Biodegradable
LiftLube Arctic part
#85803866
Waltco All Season Hyd Oil
Part 85803867
Shell Tellus S2 V 15
Mobil DTE 10 Excell 15
Chevron Rando HDZ 15
OPERATING GATE WITHOUT BATTERIES
If the liftgate needs to be operated before the batteries
are installed, temporary battery and battery charger can
be used.
BATTERY
CHARGER
Note!
Never operate liftgate only with battery charger,
this can cause damage to electrical parts.
LIFTGATE
BATTERY
GR01091
Chapter 4 Liftgate Installation
GR03015
BREATHER PLUG
Check to make sure the breather plug is installed.
Should be factory installed. Check oil level.
Replace transport plug from oil tank with breather plug.
Check oil level, oil level should be ½” below top of oil
tank.
Add oil if needed.
Do not over fill.