284 Fieldbus Communication
WAGO-I/O-SYSTEM 750
750-882 Media Redundancy ETHERNET Controller
Manual
1.5.0
12.3.5.11 Ethernet Link (F6
hex
)
The “Ethernet Link Object” contains link-specific counter and status information
for an Ethernet 802.3 communications interface. Each device must support
exactly one instance of the Ethernet Link Object for each Ethernet IEEE 802.3
communications interface on the module. An Ethernet link object instance for an
internal interface can also be used for the devices, e.g. an internal port with an
integrated switch.
Instance 0 (Class Attributes)
Table 221: Ethernet link (F5
hex
) – Class
Attribute ID Acces
s
Name
Data type Description
Default value
1
Get
Revision
UINT
Revision of this object
3 (0x0003)
2
Get
Max Instance
UDINT
Max. number of instances
3 (0x0003)
3
Get
Num Instances UDINT
Number of the current instanced
connections
3 (0x0003)