Fault at the hydraulic system
Error/malfunction
Possible cause
Remedy
Hydraulic system
overheats
Continuous operation of the hydraulic connec-
tions is switched on and operates against
pressure
Switch off continuous operation of hydraulic
connections
Dirty hydraulic oil radiator
Cleaning
Insufficient V-belt tension
Tensioning the V-belt
Malfunctioning fan blade drive
Take the machine to a service center
Incorrect hydraulic oil level
Correct the hydraulic oil level
Load too high
Reduce the load on the machine, take breaks