Cotter Corporation (N.S.L.)
Cañon City Milling Facility
Cañon City, Colorado
Procedure
Weather Monitoring
Number: SOP-E-130
Page 5 of 10
Version: 1
Date: --/--/--
8.2.7
Correct any problems found or notify the EC.
8.2.8
Complete the Weather Station Inspection Report form RSD-101r.
8.3
Semiannually, calibrate the following sensors as specified in the MET ONE
Operations and Calibration Manual. Record the calibration data on form RSD-
104r.
8.3.1
Wind speed sensor.
8.3.2
Wind direction sensor.
8.3.3
Temperature sensor.
8.3.4
Sigma meter (standard deviation of the wind direction).
8.3.5
Rainfall and evaporation equipment.
8.3.6
See the MET ONE Operations and Calibration Manual for other
maintenance and troubleshooting.
8.4
Monthly, download and reformat the meteorological data for inclusion in the
annual summary report. The total evaporation and precipitation for the year are to
be included along with a wind rose for the year.
9.0
RECORDS
9.1
Meteorological monitoring station inspection and calibration report forms.
9.2
Meteorological monitoring summary report.
9.3
All records produced by Cotter’s meteorological station will be entered into
Cotter’s Document Control System.
Summary of Contents for sympHony
Page 12: ...VWR sympHony Meter User Guide Exhibit 5 2...
Page 69: ...254503 001 Rev B...