Cotter Corporation (N.S.L.)
Cañon City Milling Facility
Cañon City, Colorado
Procedure
Radon Flux Measurement
Number: SOP-E-120
Page 3 of 8
Revision: 1
Date: --/--/--
5.1.1.
Large area canister-type radon flux collectors (LACC)
5.1.2.
Shovel
5.1.3.
Funnel apparatus
5.1.4.
Awl
5.1.5.
High/low temperature recording thermometer
5.1.6.
Rain gauge
5.2.
MATERIALS
5.2.1.
Sealed containers of unexposed specification charcoal.
5.2.2.
Garmin eMap global positioning satellite unit or equivalent.
5.2.3.
Black electrical container sealing tape.
5.3.
MAINTENANCE/CALIBRATION
5.3.1.
None for this procedure
6.0
HEALTH AND SAFETY
6.1.
Use appropriate personal protective equipment (PPE) when performing tasks
required by this procedure.
6.2.
Monitoring equipment may offer pinch points. Workers should be cautious during
monitoring activities.
7.0
RESPONSIBILITY
7.1.
The Quality Assurance Manager is responsible for:
7.1.1.
Administering principals to assure adherence to procedures and policies
found in the QAPP current version.
7.2.
The EC is responsible for:
7.2.1.
Insuring that the field staff assigned to deploy and retrieve monitoring
canisters is properly trained.
7.2.2.
Scheduling of the radon flux measurement effort.
7.3.
The Field sampling staff is responsible for: