Programming
Forms
Installation and Programming Manual
A-5
PBX PARAMETERS
OPERATION
COMMAND
SECTION
No. of digits in extension
*300 + X
3.3
Cut off time for continuous call
progress tone detection
*301 + X
X = cut off time in seconds (0-9)
Default: 6 sec.
3.3
No. of rings before the line is
answered
*310 + line number of rings
3.3
Time to wait for No Answer
*311 + XX
3.3
PBX legal extensions
*320 + Y + First Ext. + Last Ext. + #
Y = group number (0-9)
3.3
Delete all PBX legal extensions
*320 + #
3.3
Operator ID code
*330 + X
X = 0-9
3.3
Key To retrieve messages during
mailbox greeting play back
*331 + X
X = 0-9; Retrieve digit
5.2
Disconnect code
*333 + Code
1
+ #
3.3
Delete disconnect code
*333 + #
3.3
External access code
*340 + X + #
X = external access digit (0-9), Pause (*1)
3.3
Clear external access code
*340 + #
3.3
Pause before and after external
access code
*341 + X
X = pause length in seconds (0-9)
Default: 2 sec.
3.3