Option
Instructions
To test the microwave range of the dual detector:
1.
Press
to enter the "
TEST ONE DEVICE
" sub menu and use
to
navigate to "
MOTION SENSORS
".
2.
Press
; the following screens will appear: "
Z01:Motion Sens
"
<location>
.
3.
Press
continuously to select a different zone number.
4.
Press
; If the selected device is Tower-32AM PG2, the following screens will
appear: "
<OK MW ADJUST>
"
"<NEXT> TEST ONE"
.
To test the microwave range, go to step 5. To test a different microwave range, go to
step 7.
5.
Press
; the following screen will appear: "
ACTIVATE MW NOW
".
6.
Activate the device; the screen will return to "
TEST ONE DEVICE
".
You can now repeat the procedure for another dual detector.
7.
Press
to select the sensitivity setting.
8.
Press
continuously to select between "
Minimum
" (default), "
Medium
" or
"
Maximum
"
9a
. Press
; the panel will receive an acknowledgement from the device that is
indicated by a black box next to the selected setting. Thereafter, the screen
momentarily changes to "
ACTIVATE MW NOW
" and then returns to the selected
setting.
9b
. If you press
, the adjustment procedure ends.
Important
: The procedure mentioned above is for testing purposes only and does not
change the detector settings. The settings must be saved through the
MODIFY DEVICES menu.
To test the shock detector:
1.
Press
to enter the "
TEST ONE DEVICE
" sub menu and use
to
navigate to "
SHOCK SENSORS
".
2.
Press
; the following screens will appear: "
Zxx:Shk+AX+CntG3
"
13
<location>
.
3.
Press
continuously to select a different zone number.
4.
Press
; the following screens will appear: "
Zxx ACTIVATE NOW
"
"SHOCK NOT ACTIV
."
"CNTACT NOT ACTIV
"
"AUXIL. NOT ACTIV
".
Note:
The above screens are the full range of screens that can appear and indicate
the inputs that have not yet been activated. However, since there are various
models of the shock detector, not all of these screens will appear on some models.
5.
At this stage, activate each input of the shock detector in turn.
13
Depending on shock detector model, one of the following may appear instead: "
Zxx:Shk+AX
" / "
Zxx:Shk+CntG3
" /"
Zxx:Shk+CntG2
".
D-306919 KP-250 PG2 Installer’s Guide
85