3.4.6 Configuring Soak Test Mode
This option enables you to enter device zones into Soak Test mode.
To
Enable
the Soak Test, complete the following steps:
Step 1
Step 2
Select "ADD TO SOAK TEST"
Option
[1]
Select the respective device Group
[2]
02:ZONES/DEVICES
CONTACT SENSORS
ADD TO SOAK TEST
MOTION SENSORS
Step 3
Step 4
Select device zone number
[3]
Press
to make selection
Z09:Motion-Sens
ID No. 120-2468
Z09:Motion Sens
disable
Step 5
Step 6
Step 7
Select to enable or disable Soak Test
[4]
Confirm selection
[5]
to Step 4
Z09:Motion-Sens
disable
Z09:Motion-Sens
enable
Z09:Motion-Sens
enable
– Enabling Soak Test mode
[1]
Enter the
Installer Menu
, select the "
02.ZONES/DEVICES
"
option (see section 3.2) and then select the
"ADD
TO SOAK TEST"
option.
[2]
Select the respective Group of the device you wish to add the Soak Test. For example, "
MOTION SENSORS
".
[3]
Scroll to select the specific device zone number.
[4]
Select between “
disable
” (default) or “
enable
” test.
[5]
If set to “
enable
” you must set the duration of the Soak Test before the Soak Test will start (see Section 3.5.8).
You can stop the test for the relevant zone by changing the setting to "
disable
" at any time during the testing
period.
All Soak test zones will be reset to start a new test upon occurrence of one of the following: 1) Power
up of the system;
2)
Setup of Factory Default;
3)
Change in system Soak Time
.
22