Option
Instructions
SIRENS TEST
You can test wireless sirens and strobes and sirens of smoke sensors and keypads.
To initiate the siren test press
.
The display now reads "
SIREN N
"
“<NEXT> or
<OK>”
. "
N
" indicates the zone location assigned to the siren that is currently being tested.
First the panel siren sounds for 1 second after which the PowerMaster system will
automatically repeat the procedure for the next siren enrolled in the system until all sirens
are tested. You should listen to the sirens sounds and make sure that all sirens sound.
Once all the sirens have been tested, the control panel will now test the sirens of smoke
sensors that are enrolled in the alarm system. The display now reads "
Zxx: SMOKE
SIREN
"
“<NEXT> or <OK>”
, where "
Zxx
" indicates the zone number of the smoke
sensor. During this time, the siren of the tested smoke sensor will sound for 10 seconds.
Press
to test the siren of the next smoke sensor.
Once all the sirens of the smoke sensors have been tested, the control panel will now
test the sirens of keypads that are enrolled in the alarm system. The display now reads
"
Kxx: KEYPAD SIREN
"
“<NEXT> or <OK>”
, where "
Kxx
" indicates the zone number
of the keypad. During this time, the siren of the tested smoke sensor will sound for 10
seconds.
When the sirens test is complete, the display reads "
SIREN TEST ENDED
". Press the
or the
button to confirm the test.
TEMP/LIGHT
The KP-250 PG2 reads the temperature and light intensity of the zone.
When testing, all previous temperature and light results from sensors are cleared.
To display the temperature and light intensity of zones on the KP-250 PG2, press
. After 20 seconds, the KP-250 PG2 displays the temperature, the sensor number
and the sensor location, as in the following example: "
Z01 24.5
°
C
"
"
Z01:Temp.
Sensor
" changes to "
Custom
". Repeatedly click the
button to review the
temperature of each zone (by Temperature Sensor). If there is no result the following
message is displayed:
Zxx TEMP: No TST
.
The light level indication is dynamic, that is, if a detector has only two light thresholds
defined, the following displayed on the KP-250 PG2:
• For 100% light: LIGHT (**)
• For complete darkness: LIGHT ()
If there is no light result, the following message is displayed:
Zxx LIGHT: No TST
.
The display alternates between the temperature, light sensor number, and the sensor
location, as in the following example:
Z01 24.5°C > Z01: LIGHT (**) > Z01: Sensor
number > Room location.
When the temperature and light of all zones has been reviewed, the display reads
"
DEVICE TEST ENDED
". Press the
or the
button to confirm the test and
then move to the next step to test the other devices.
TEST ALL DEVICES
You can test all devices in one procedure.