Option
Instructions
VOICE LOC.#1
Dining room
You can record zone names (for example, Garage door, Guest room, etc.), and assign
them to specific zones. When done, press
to return.
Press
to select the zone name you wish to record, for example "
VOICE LOC.
#01
" and the current recording for zone name, for example, "
Dining room
".
Record zone names; the procedure is identical to the "
RECORD HOUSE ID
" recording
procedure described above. Click
to navigate between zone name numbers.
IMPORTANT!
1.
The
editing of a custom zone name automatically deletes the original text and recorded voice name. Make sure to
record a new voice name.
2.
Performing reset of factory defaults (see section 3.11) restores the original recordings for the zone names.
3.8.3 Voice Box Mode
7
This mode allows you to determine whether two-way voice communication is to be sounded either via an external
speakerphone, via the control panel, or via both.
For the two-way voice communication procedure, follow the instructions below. Additional details and guidance are
provided in section 3.2.
06:CUSTOM NAMES
⋅⋅⋅
VOICE BOX MODE
Enter "
VOICE BOX MODE
", and then refer to the table below which provides you with the options.
Option and default
Instructions
VOICE BOX MODE
VOICE BOX MIXED
Define whether two-way voice communication is to be sounded either via the external
speakerphone ("
VOICE BOX ONLY
"), via the control panel ("
NO VOICE BOX
"), or via
both ("
VOICE BOX MIXED
").
Options: NO VOICE BOX; VOICE BOX ONLY
and
VOICE BOX MIXED
3.9 Diagnostics
3.9.1 General Guidance – "Diagnostics" Flow-Chart & Menu Options
The DIAGNOSTICS menu enables you to test your system and to verify proper operation of your PowerMaster panel,
wireless devices attached to it and the communication (GSM/GPRS) modules.
IMPORTANT!
Reliable reception must be assured during the initial testing and also throughout subsequent system
maintenance. A
device should not be installed in location where signal strength is "poor".
If you get "poor" signal
strength from a certain device, simply re-locate it and re-test until a "good" or "strong" signal strength is received. This
principle should be followed throughout the diagnostic test procedure
.
The diagnostic test process is shown below.
The "
07.DIAGNOSTICS
" menu contains several sub-menu options, each covering a group of configurable features and
parameters related to the communication and reporting as follows (see the list in Step 3 of the chart below):
7
Refers to system that is connected to the Voice Box
D-306919 KP-250 PG2 Installer’s Guide
63