Option and default
Configuration Instructions
Options:
rprt disabled
,
rprt ena+bypass
and
rprt enabled
Note:
In some PowerMaster variants, this menu is displayed in the Operation Mode only.
62:RECENT CLOSE
rprt disabled
False alarms may occur if users do not exit the premises within the exit delay period,
resulting in a false alarm a short time later. In such cases, inform the Monitoring Station that
the alarm occurred shortly after the system was armed (this event is known as "Recent
Close"). The report enabled option sends a “recent closing” report to the Monitoring Station
if an alarm occurs within 2 minutes from the end of the exit delay.
Options:
rprt disabled
and
rprt enabled
63:ZONE RESTORE
rprt disabled
Some Monitoring Stations require that following an alarm event from a specific zone, the
system will also report when the alarming zone has restored to normal.
Options:
rprt enabled
and
rprt disabled
64:SYST.INACTIVE
rprt disabled
The PowerMaster can report a "System Inactive" event message (CID event 654) to the Monitoring
Station if the system is not used (i.e. armed) during a predefined time period.
Options:
rprt disabled
;
after 7/14/30/90 days
.
65:TWO WAY
VOICE
You can configure the two way voice channel settings of the control panel
4
, as follows:
Send 2 WV Code:
Define whether the system will send two-way voice code to the Monitoring
Station (to turn the Monitoring Station from data communication to voice communication state)
by using pre-selected SIA or Contact-ID communication format only.
voice c.s.:
Select the timeout for 2-way voice communication with Monitoring Stations, or
enable the Monitoring Station to ring back for 2-way voice function. This option is applicable only
after reporting an event to the Monitoring Station for listening and speaking.
ringback Time:
Define the period during which the Monitoring Station can establish 2-way voice
communication with the control panel (after 1 ring), if:
A. Alarm type message was received by Monitoring Station.
B. Ring Back function was selected (see “Voice <--> C.S.” sub menu above).
Ambient Level:
Select the ambient noise level of the installation. If it is a relatively noisy
environment, set it to High (default setting). If it is a very quiet environment, set to Low.
Send 2wv code
disable
voice<- ->cs
disable
ringback time
1 minute
ambient level
low
(Return)
Master Installer only
for:
Send 2wv code /
voice <
−
−
>cs /
4
Refers to PowerMaster-30 G2 with voice option.
D-306919 KP-250 PG2 Installer’s Guide
47