- Configuring New Devices
[9]
To review or change the
Device Configuration
(settings)
, press the
button, otherwise scroll to the
next option – see
[11].
[10]
To configure the device parameters, refer to its corresponding device datasheet in the device Installation
Instructions. The defaults of the device parameters can be also configured as explained in section 3.4.7.
[11]
After completing the configuration of the device, the wizard brings you to the
"Next Step"
menu with the
following 3 options:
"
NEXT Device
" to enroll the next device.
"
MODIFY Same Dev.
" reverts to Step 1 (i.e. "
LOCATION
") to allow you to perform additional changes to the
device, if needed.
"
EXIT Enrollment
" exits the enrollment procedure and returns to Step 1 bringing you back to the "
ADD
NEW DEVICES
" menu.
Location List
No.
Location Name
No.
Location Name
No.
Location Name
01
Admin Office
09
Marketing Office
17
Sales Office
02
Delivery door
10
Mezzanine Floor
18
Server Room
03
Engineering
11
Post Room
19
Store Room
04
Finance
12
Rear Doors
20
Warehouse
05
Fire Exit
13
Rr Fire Exit Dr
21
Warehouse
doors
06
Front Doors
14
Rear Lobby
07
Front Shop
15
Rear Shop
08
Landing Area
16
Reception
All location names be customized by “06:CUSTOM NAMES” menu (see section 3.8)
Zone Type List
Zone No. and Type
Description
Zxx: ZONE TYPE
1. Exit/Entry 1
This Zone starts the exit time when the user arms the system or the entry time
when the system is armed. To configure the Exit/Entry 1 time, see section 3.14
- Operation mode menu:
13: OPERATION MOD -> 02:BS8243 SETUP or
03:DD243 SETUP or 05:EN50131 SETUP -> 08:ENTRY DELAY 1
Zxx: ZONE TYPE
2. Exit/Entry 2
Same as Exit / Entry 1 but with a different delay time. Used sometimes for
entrances closer to the panel. To configure the Exit and Entry 2 delays, see
section 3.14 - Operation mode menu:
13.OPERATION MOD -> 02:BS8243
SETUP or 03:DD243 SETUP or 05:EN50131 SETUP -> 09:ENTRY DELAY 2
Zxx: ZONE TYPE
3. Home E/E)
(Home/Delay)
The Home Exit and Entry zone is used for Door/Window Contacts and Motion
sensors protecting entrance doors to interior living areas where you wish to
move freely when the system is armed HOME. Functions as a "Delayed" zone
when the system is armed HOME and as a "Perimeter Follower" zone when the
system is armed AWAY.
Zxx: ZONE TYPE
4. Inter-Access
(Inter-follow)
Similar to "Interior" zone but temporarily ignored by the alarm system during
entry/exit delay periods. Usually used for sensors protecting the route between
the entrance door and the panel.
Zxx: ZONE TYPE
5. Interior
This zone type generates an alarm only when the system is armed AWAY but not
when the system is armed HOME. Used for sensors installed in interior areas of
the premises that needs to be protected when people are not present inside the
premises.
Zxx: ZONE TYPE
6 .Perimeter
This zone type generates an alarm when the system is armed both in AWAY
and HOME modes. Used for all sensors protecting the perimeter of the
premises.
D-306919 KP-250 PG2 Installer’s Guide
17