59
13.7 AUXILIARY OUTPUT MANAGEMENT
The GSM chronothermostat 01913 is equipped with an auxiliary output to control a generic load�
This load must be controlled solely via an external auxiliary relay
(not supplied)�
The functions that can be used for managing the auxiliary output are given in the following points�
13.7.1 Customizing the SMS label for the auxiliary output
This setting enables defining a text to associate with the auxiliary output; to be used as an alternative
to the default label R1 in the SMS command messages�
For setting the output SMS label send the following SMS message:
<user code>.R1.STR.<text>
where
<text>
is the description to associate with the input (max 20 characters)�
Note
: No response SMS message is required from the chronothermostat 01913; do not use the “
.
”
and “
/
” characters�
Example�
If the set user code is the default 1234 and you want to associate the “staircase light” name with the
auxiliary output, send the following SMS message:
1234.R1.STR.staircase light
To delete customizing the auxiliary output SMS label, send the following message:
<user code>.R1.STR.O
where
0
is the number zero�
Note
: No response SMS message is required from the chronothermostat 01913�
Example�
If the set user code is the default 1234 and you want to delete the auxiliary output customization text,
send the following SMS message:
1234.R1.STR.0