To disable it, send the following SMS message:
<user code>.AR.OFF
Note
: No response SMS message is required from the chronothermostat 01913�
Example
If the set user code is the default 1234 and you want to disable management of the alarm for no mains
power/restored mains power, send the following SMS:
1234.AR.OFF
To read the setting made on the alarm for no mains power/restored mains power, send the following
SMS message:
<user code>.?AR
The chronothermostat 01913 will send an SMS reply message with the following format:
GSM-01913 1/1
AR
ENABLED:ON/OFF
TOFF:5s
TON:5s
Example�
If the set user code is the default 1234 and the alarm for no mains power/restored mains power has
been enabled, on sending the SMS message:
1234.?AR
The chronothermostat 01913 will send the following SMS response message:
GSM-01913 1/1
AR
ENABLED:ON
TOFF:5s