Type AWOT-E/AWOT-E-AC
221.A10
221.A13
221.A16
Integral DHW cylinder
Capacity
l
220
220
220
Max. draw-off volume at DHW temperature 40 °C, storage
temperature 53 °C and draw-off rate 10 l/min
l
290
290
290
Performance factor N
L
to DIN 4708
1.6
1.6
1.6
Max. draw-off rate at the specified performance factor N
L
and DHW heating from 10 to 45 °C
l/min
17.3
17.3
17.3
Max. permissible DHW temperature
°C
70
70
70
Outdoor unit dimensions
Total length
mm
546
546
546
Total width
mm
1109
1109
1109
Total height
mm
1377
1377
1377
Indoor unit dimensions
Total length
mm
681
681
681
Total width
mm
600
600
600
Total height
mm
1874
1874
1874
Total weight
Outdoor unit
kg
153
153
153
Indoor unit
kg
164
164
164
Indoor unit with filled DHW cylinder
kg
384
384
384
Permissible operating pressure
, secondary side
bar
3
3
3
MPa
0.3
0.3
0.3
Secondary circuit connections
(with connection acces-
sories, female thread)
Heating water flow
G
1¼
1¼
1¼
Heating water return
G
1¼
1¼
1¼
DHW
G
¾
¾
¾
Cold water
G
¾
¾
¾
DHW circulation
G
¾
¾
¾
Secondary circuit flow
G
1¼
1¼
1¼
Secondary circuit return
G
1¼
1¼
1¼
Length of connection line between indoor and out-
door units
(Hydraulic connection set)
m
1 to 20
1 to 20
1 to 20
Sound power of outdoor unit
at rated heating output
(Measurements with reference to EN 12102/
EN ISO 9614-2)
Weighted total sound power level
– At A7
±3 K
/W55
±5 K
(max.)
dB(A)
61
61
61
– At A7
±3 K
/W55
±5 K
in night mode
dB(A)
55
55
55
Energy efficiency class
to EU Regulation no. 813/2013
Heating, average climatic conditions
– Low temperature applications (W35)
A
+++
*10
A
+++
*10
A
+++
*10
– Medium temperature applications (W55)
A
++
A
++
A
++
DHW heating, draw-off profile (L)
A
A
A
Performance data
as per EU Regulation no. 813/2013
(average climatic conditions)
Low temperature applications (W35)
– Energy efficiency η
S
%
180
182
182
– Rated heating output P
rated
kW
9.75
10.99
11.65
– Seasonal coefficient of performance (SCOP)
4.58
4.64
4.62
Medium temperature applications (W55)
– Energy efficiency η
S
%
132
134
134
– Rated heating output P
rated
kW
9.67
11.00
11.98
– Seasonal coefficient of performance (SCOP)
3.37
3.42
3.42
– DHW heating energy efficiency η
wh
%
117
117
117
Sound power level to ErP
Sound power level, outdoor unit
dB(A)
56
56
56
Note
Reduced noise night mode can be enabled at the heat pump control
unit at the "Contractor" setting level.
*10
The new energy efficiency class A
+++
comes into effect on 26 September 2019.
Vitocal 222-A
(cont.)
22
VIESMANN
VITOCAL
3
5831388