Cooling
■
Vitocal 200-A
, type AWO-M-E-AC 201.A10
■
Vitocal 222-A
, type AWOT-M-E-AC 221.A10
Cooling capacity at flow temperatures 18 °C, 7 °C
7 °C
18 °C
0
P in kW
20
ϑ in °C
2
4
6
10
8
25
30
35
40
45
Power consumption for cooling at flow temperatures 18 °C, 7 °C
18 °C
7 °C
4
0
P
el
in kW
ϑ in °C
20
3
2
1
25
30
35
45
40
Performance factor EER at flow temperatures of 18 °C, 7 °C
EER
ϑ in °C
20
0
7 °C
18 °C
6
2
4
8
10
25
30
35
40
45
ϑ
Air intake temperature
P
Cooling capacity
P
el
Power consumption
EER Coefficient of performance
Note
■ The EER data in the tables and diagrams was calculated with ref-
erence to EN 14511.
■ Performance characteristics apply to new appliances with clean
plate heat exchangers.
Operating point
W
°C
18
A
°C
20
25
27
30
35
40
45
Cooling capacity
kW
8.81
8.19
8.00
7.60
7.00
6.41
5.86
Power consumption
kW
1.09
1.29
1.38
1.50
1.71
1.93
2.20
Energy efficiency ratio EER
8.11
6.34
5.81
5.06
4.10
3.32
2.71
Operating point
W
°C
7
A
°C
20
25
27
30
35
40
45
Cooling capacity
kW
6.66
6.12
5.90
5.58
5.00
4.63
4.20
Power consumption
kW
1.36
1.55
1.62
1.73
1.90
2.13
2.33
Energy efficiency ratio EER
4.89
3.96
3.65
3.22
2.70
2.17
1.80
Curves