2.2 Specification
Specification
230 V appliances
Type AWO-M/AWO-M-E/AWO-M-E-AC
201.A04
201.A06
201.A08
201.A10
201.A13
201.A16
Heating performance data
to EN 14511 (A2/W35)
Rated heating output
kW
2.61
3.11
4.04
5.01
5.92
6.47
Fan speed
rpm
600
600
650
600
600
600
Power consumption
kW
0.73
0.82
1.02
1.27
1.48
1.79
Coefficient of performance ε (COP) in
heating mode
3.57
3.78
3.96
3.96
4.01
3.61
Output control
kW
2.00 to 4.10 2.40 to 5.50 2.80 to 7.00 4.40 to 9.60
4.80 to
10.20
5.20 to
10.70
Heating performance data
to EN 14511 (A7/W35, 5 K
spread)
Rated heating output
kW
3.96
4.83
5.62
7.01
7.85
8.64
Fan speed
rpm
600
600
650
600
600
600
Air flow rate
m
3
/h
2250
2250
2600
4500
4500
4500
Power consumption
kW
0.87
1.02
1.19
1.49
1.66
1.90
Coefficient of performance ε (COP) in
heating mode
4.56
4.72
4.71
4.69
4.72
4.54
Output control
kW
2.44 to 4.18 3.00 to 6.00 3.47 to 7.54
5.48 to
12.60
6.00 to
13.70
6.42 to
14.30
Heating performance data
to EN 14511 (A–7/W35)
Rated heating output
kW
3.81
5.70
6.67
8.69
9.50
11.03
Power consumption
kW
1.31
1.96
2.31
2.77
3.09
3.90
Coefficient of performance ε (COP) in
heating mode
2.91
2.91
2.89
3.14
3.07
2.83
Heating performance data
to EN 14511 (A35/W7)
Rated cooling capacity
kW
2.00
3.00
4.00
5.00
6.00
7.00
Fan speed
rpm
600
600
650
900
900
900
Power consumption
kW
0.80
1.20
1.40
1.90
2.30
2.70
Energy efficiency ratio EER in cooling
mode
2.40
2.60
2.90
2.70
2.65
2.60
Output control
kW
Up to 3.90
Up to 4.90
Up to 6.20
Up to 8.00
Up to 9.00
Up to 10.30
Heating performance data
to EN 14511 (A35/W18)
Rated cooling capacity
kW
4.00
5.00
6.00
7.00
8.20
9.20
Fan speed
rpm
600
600
650
900
900
900
Power consumption
kW
0.80
1.35
1.40
1.67
2.08
2.42
Energy efficiency ratio EER in cooling
mode
4.20
4.20
4.30
4.10
3.95
3.80
Output control
kW
Up to 5.00
Up to 6.00
Up to 7.00
Up to 11.00 Up to 12.50
Up to 13.90
Air intake temperature
Cooling mode (type AWO-M-E-AC only)
– Min.
°C
10
10
10
10
10
10
– Max.
°C
45
45
45
45
45
45
Heating mode
– Min.
°C
–20
–20
–20
–20
–20
–20
– Max.
°C
35
35
35
35
35
35
Heating water
(secondary circuit)
Minimum flow rate
l/h
700
700
700
1400
1400
1400
Minimum volume in the heating system,
cannot be fitted with shut-off devices
l
50
50
50
50
50
50
Max. external pressure drop (RFH) at
minimum flow rate
mbar
705
705
705
500
500
500
kPa
70.5
70.5
70.5
50
50
50
Max. flow temperature
°C
60
60
60
60
60
60
Outdoor unit electrical values
Rated voltage, compressor
1/N/PE 230 V/50 Hz
Max. operating current, compressor
A
13.0
14.6
14.6
19.9
23.3
23.3
Cos φ
0.99
0.99
0.99
0.99
0.99
0.99
Starting current, compressor
A
15
15
15
15
15
15
Fuse rating
B16 A
B16 A
B16 A
B25 A
B25 A
B25 A
IP rating
IP X4
IP X4
IP X4
IP X4
IP X4
IP X4