Vitocal 200-A, 230 V appliances
Type
´
min
in l/h
7
pipes
V
min
in l
*20
Without buf-
fer cylinder
Buffer cylinder (recommended minimum)
+
– AWO-M
– AWO-M-E
– AWO-M-E-AC
201.A04
700
DN 25
50
X
Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
201.A06
700
DN 25
50
X
Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
201.A08
700
DN 25
50
X
Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
201.A10
1400
DN 32
50
X
Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
201.A13
1400
DN 32
50
X
Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
201.A16
1400
DN 32
50
X
Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
Vitocal 200-A, 400 V appliances
Type
´
min
in l/h
7
pipes
V
min
in l
*20
Without buf-
fer cylinder
Buffer cylinder (recommended minimum)
+
– AWO
– AWO-E
– AWO-E-AC
201.A10
1400
DN 32
50
X
Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
201.A13
1400
DN 32
50
X
Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
201.A16
1400
DN 32
50
X
Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
Heating water buffer cylinder in the heat pump return
(connected in series)
Icons:
X
Possible
´
min
Minimum flow rate, secondary circuit
7
pipes
Minimum diameter of pipes in secondary circuit
V
min
Minimum volume of the heating system
Underfloor heating circuit
Radiator heating circuit
Vitocal 222-A, 230 V appliances
Type
´
min
in l/h
7
pipes
V
min
in l
*20
Without buf-
fer cylinder
Buffer cylinder (recommended minimum)
+
– AWOT-M-E
– AWOT-M-E-AC
221.A04
700
DN 25
40
*21
/50
X
Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
221.A06
700
DN 25
40
*21
/50
X
Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
221.A08
700
DN 25
40
*21
/50
X
Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
221.A10
1400
DN 32
40
*21
/50
X
Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
221.A13
1400
DN 32
40
*21
/50
X
Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
221.A16
1400
DN 32
40
*21
/50
X
Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
Vitocal 222-A, 400 V appliances
Type
´
min
in l/h
7
pipes
V
min
in l
*20
Without buf-
fer cylinder
Buffer cylinder (recommended minimum)
+
– AWOT-E
– AWOT-E-AC
221.A10
1400
DN 32
40
*21
/50
X
Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
221.A13
1400
DN 32
40
*21
/50
X
Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
221.A16
1400
DN 32
40
*21
/50
X
Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
Heating water buffer cylinder in the heat pump return
(connected in series)
Icons:
X
Possible
´
min
Minimum flow rate, secondary circuit
7
pipes
Minimum diameter of pipes in secondary circuit
V
min
Minimum volume of the heating system
Underfloor heating circuit
Radiator heating circuit
*20
Cannot be fitted with shut-off devices
*21
In conjunction with Vitocell 100-E, type SVPA, part no. ZK03801
Design information
(cont.)
VITOCAL
VIESMANN
121
5831388
7