Type AWO-M/AWO-M-E/AWO-M-E-AC
201.A04
201.A06
201.A08
201.A10
201.A13
201.A16
Energy efficiency class
to EU Regula-
tion no. 813/2013
Heating, average climatic conditions
– Low temperature applications (W35)
A
++
A
++
A
+++
*2
A
+++
*2
A
+++
*2
A
+++
*2
– Medium temperature applications
(W55)
A
+
A
++
A
++
A
++
A
++
A
++
Performance data
as per EU Regulation
no. 813/2013 (average climatic condi-
tions)
Low temperature applications (W35)
– Energy efficiency η
S
%
173
172
175
176
175
175
– Rated heating output P
rated
kW
5.38
5.59
6.82
9.32
9.99
10.61
– Seasonal coefficient of performance
(SCOP)
4.40
4.38
4.46
4.47
4.46
4.46
Medium temperature applications (W55)
– Energy efficiency η
S
%
124
125
127
129
130
130
– Rated heating output P
rated
kW
5.23
5.59
6.41
9.35
10.07
10.72
– Seasonal coefficient of performance
(SCOP)
3.18
3.21
3.25
3.29
3.32
3.34
Sound power level to ErP
Sound power level, outdoor unit
dB(A)
53
54
55
56
56
56
Note
Reduced noise night mode can be enabled at the heat pump control
unit at the "Contractor" setting level.
400 V appliances
Type AWO/AWO-E/AWO-E-AC
201.A10
201.A13
201.A16
Heating performance data
to EN 14511 (A2/W35)
Rated heating output
kW
6.10
6.67
7.02
Fan speed
rpm
600
600
600
Power consumption
kW
1.49
1.64
1.78
Coefficient of performance ε (COP) in heating mode
4.10
4.06
3.94
Output control
kW
4.40 to 10.10
4.80 to 10.70
5.20 to 11.20
Heating performance data
to EN 14511 (A7/W35, 5 K spread)
Rated heating output
kW
7.58
8.88
10.11
Fan speed
rpm
600
600
600
Air flow rate
m
3
/h
4500
4500
4500
Power consumption
kW
1.51
1.78
2.04
Coefficient of performance ε (COP) in heating mode
5.01
4.99
4.95
Output control
kW
5.45 to 13.60
5.93 to 14.20
6.40 to 14.70
Heating performance data
to EN 14511 (A–7/W35)
Rated heating output
kW
10.09
11.06
11.60
Power consumption
kW
3.17
3.60
3.87
Coefficient of performance ε (COP) in heating mode
3.18
3.07
3.00
Heating performance data
to EN 14511 (A35/W7)
Rated cooling capacity
kW
5.00
6.00
7.00
Fan speed
rpm
600
600
600
Power consumption
kW
1.90
2.30
2.80
Energy efficiency ratio EER in cooling mode
2.70
2.60
2.50
Output control
kW
Up to 8.00
Up to 9.00
Up to 10.00
Heating performance data
to EN 14511 (A35/W18)
Rated cooling capacity
kW
7.00
8.20
9.20
Fan speed
rpm
600
600
600
Power consumption
kW
1.71
2.00
2.30
Energy efficiency ratio EER in cooling mode
4.10
4.10
4.00
Output control
kW
Up to 8.00
Up to 9.00
Up to 10.00
Air intake temperature
Cooling mode (type AWO-E-AC only)
– Min.
°C
10
10
10
– Max.
°C
45
45
45
Heating mode
– Min.
°C
–20
–20
–20
– Max.
°C
35
35
35
*2
The new energy efficiency class A
+++
comes into effect on 26 September 2019.
Vitocal 200-A
(cont.)
VITOCAL
VIESMANN
11
5831388
2