Functions
■ Electronic maximum and minimum temperature limit
■ Demand-dependent shutdown of the heat pump and the pumps for
the primary and secondary circuits
■ Adjustment of a variable heating and cooling limit
■ Pump anti-seizing protection
■ Monitoring frost protection of system components
■ Integral diagnostic system
■ Cylinder temperature controller with priority control
■ Auxiliary function for DHW heating (short-term heating to a higher
temperature)
■ Control of a heating water buffer cylinder
■ Screed drying program
■ External hook-ups: Mixer OPEN, mixer CLOSE, changeover of
operating mode (with external EA1 extension, accessories)
■ External demand (adjustable set flow temperature) and heat pump
blocking, specifying the set flow temperature via an external 0 to
10 V signal (with external EA1 extension, accessories)
■ Function check of controlled components, e.g. circulation pumps
■ Optimised utilisation of power generated by the photovoltaic sys-
tem (on-site power consumption)
■ Control and operation of compatible Viessmann ventilation units
Functions subject to heat pump type
Function
Vitocal 200-A, type
Vitocal 222-A, type
AWO(-M)
201.A
AWO(-M)-E
201.A
AWO(-M)-E-AC
201.A
AWOT(-M)-E
221.A
AWOT(-M)-E-AC
221.A
Weather-compensated control of the flow temperatures for heat-
ing or cooling mode
– System flow temperature or flow temperature for heating circuit
without mixer A1/HC1
X
X
X
X
– Flow temperature for heating circuit with mixer M2/HC2:
Direct control of the mixer motor by the control unit
X
X
X
X
– Flow temperature, heating circuit with mixer M3/HC3:
Control of the mixer motor via the KM-BUS
X
X
X
X
– Flow temperature when cooling via a heating/cooling circuit or sep-
arate cooling circuit without buffer cylinder or in conjunction with a
heating water buffer cylinder
X
X
– Flow temperature when cooling via max. 3 heating/cooling circuits
in conjunction with a heating water/coolant buffer cylinder
X
X
Active cooling function (AC)
X
X
Solar DHW heating/central heating backup
with graphic represen-
tation of solar yield
Solar circuit pump
with
switching via PWM signal:
– Control unit with solar control module, type SM1 (accessories)
– Control unit with SDIO/SM1A electronics module (integrated in So-
lar-Divicon, type PS 10)
X
X
X
*22
X
*22
Instantaneous heating water heater switching
X
X
X
X
External heat generator switching
(e.g. oil/gas boiler)
X
X
Control of swimming pool heating
– Control via EA1 extension
X
X
X
X
Heat pump cascade switching
– For up to 5 Vitocal via LON (LON communication module required,
accessory)
X
X
Connection to higher KNX/EIB system via Vitogate 200, type
KNX
(LON communication module required, accessory)
X
X
X
X
*22
In conjunction with solar indirect coil set (accessory)
Heat pump control unit
(cont.)
VITOCAL
VIESMANN
131