5.2 Performance diagrams, outdoor unit types 201.A06 and 221.A06, 230 V~
Heating
Vitocal 200-A
, type
■ AWO-M 201.A06
■ AWO-M-E 201.A06
■ AWO-M-E-AC 201.A06
Vitocal 222-A
, type
■ AWOT-M-E 221.A06
■ AWOT-M-E-AC 221.A06
Heating output at flow temperatures of 35 °C, 45 °C, 55 °C, 60 °C
10
8
6
4
2
0
-20
-15
-10
-5
0
5
10
15
20
25
30
P in kW
35 °C
45 °C
55 °C
60 °C
ϑ in °C
Possible output range
Power consumption at flow temperatures of 35 °C, 45 °C, 55 °C, 60 °C
4
2
0
-20
-15
-10
-5
0
5
10
15
20
25
30
60 °C
55 °C
45 °C
35 °C
ϑ in °C
P
el
in kW
Coefficient of performance COP at flow temperatures of 35 °C,
45 °C, 55 °C, 60 °C
6
4
2
0
8
-20 -15 -10 -5 0
5 10 15 20 25 30
COP
45 °C
60 °C
35 °C
55 °C
ϑ in °C
ϑ
Air intake temperature
P
Heating output
P
el
Power consumption
COP Coefficient of performance
Note
■ The COP data in the tables and diagrams was calculated with ref-
erence to EN 14511.
■ Performance characteristics apply to new appliances with clean
plate heat exchangers.