148
20,5
97
Specification
Power supply
Via KM-BUS
Power consumption
0.2 W
Protection class
III
IP rating
IP 30 to EN 60529; ensure through de-
sign/installation
Permissible ambient temperature
– Operation
0 to +40 °C
– Storage and transport
−20 to +65 °C
Setting range of the set
room temperature for
standard mode
3 to 37 °C
Notes
■ If the Vitotrol 200-A is to be used for room temperature hook-up,
site the device in a main living room (lead room).
■ Connect maximum 3 Vitotrol 200-A units to the control unit.
9.4 Wireless remote control units
Information on Vitotrol 200-RF
Wireless remote control unit with integral wireless transmitter for
operation with the wireless base station.
A Vitotrol 200-RF can be used for each heating or cooling circuit.
The Vitotrol 200-RF can operate one heating/cooling circuit.
Up to 3 wireless remote control units can be connected to the control
unit.
Note
The wireless remote control unit
cannot
be combined with a hard-
wired remote control.
Vitotrol 200-RF
Part no. Z011219
Wireless subscriber
■ Displays:
– Room temperature
– Outside temperature
– Operating condition
– Wireless signal reception quality
■ Settings:
– Set room temperature for standard mode (normal room tempera-
ture)
Note
The set room temperature for reduced mode (reduced room
temperature) is set at the control unit.
– Operating program
■ Party and economy mode can be enabled via keys
■ Integral room temperature sensor for room temperature hook-up
(only for one heating circuit with mixer)
Installation location:
■ Weather-compensated mode:
Installation anywhere in the building
■ Room temperature hook-up:
The integral room temperature sensor captures the room tempera-
ture and effects any necessary correction of the flow temperature.
The captured room temperature depends on the installation site:
– Main living room on an internal wall opposite radiators
– Not on shelves or in recesses
– Never in the immediate vicinity of doors or close to heat sources
(e.g. direct insolation, fireplace, TV set, etc.)
Note
Observe the "Wireless accessories" technical guide.
148
20,5
97
Specification
Power supply
2 AA batteries 3 V
Radio frequency
868 MHz
Wireless range
See "Wireless accessories" technical
guide
Protection class
III
IP rating
IP 30 to EN 60529; ensure through de-
sign/installation
Permissible ambient temperature
– Operation
0 to +40 °C
– Storage and transport
−20 to +65°C
Setting range of the set
room temperature for
standard mode
3 to 37 °C
Control unit accessories
(cont.)
138
VIESMANN
VITOCAL
9