Vitocal 200-A
Heat pump operating mode
3 to 5 occupants
6 to 8 occupants
DHW cylinder
Capacity
DHW cylinder
Capacity
Mono mode
Vitocell 100-V/100-W, type CVAA
300 l Vitocell 100-V, type CVA
500 l
Vitocell 100-V, type CVWA
300 l
390 l
Vitocell 100-V, type CVWA
500 l
Vitocell 100-L, type CVL
+ cylinder loading system
500 l
Dual mode
Vitocell 100-V/100-W, type
CVBB
300 l Vitocell 100-V/100-W, type
CVBB
500 l
To ensure the DVGW Directive is fulfilled, an instantaneous heating
water heater or second heat generator should be installed, so that
DHW temperatures reach > 60 °C. Equipping the heat pump with an
instantaneous heating water heater fulfils this requirement.
DHW cylinder specification
See technical guides for DHW cylinders.
System examples
DHW cylinder with internal indirect coils
WW
KW
Hydraulic scheme when using Vitocell 100-V, type CVWA
A
Heat pump connection
B
Immersion heater EHE can be installed in top or bottom sec-
tion
KW
Cold water
DHW DHW
WW
KW
A
WW
rR
eR
rZ
rW
B
Hydraulic scheme when using Vitocell 100-B, type CVBB or
Vitocell 100-W, type CVBB, 300 l (as dual mode system) or
Vitocell 100-V, type CVAA, 300 l
A
External heat generator connection
B
Heat pump connection
KW
Cold water
DHW DHW
Equipment required
Pos.
Designation
Quantity
Part no.
eR
Cylinder temperature sensor
1
7438702
rW
Spring-loaded check valve
1
On site
rR
Immersion heater EHE
1
See Viessmann pricelist.
rZ
DHW circulation pump
1
See Vitoset pricelist.
rI
DHW cylinder
1
See Viessmann pricelist.
7.13 Hydraulic connection of the cylinder loading system (for heat pump cascade with
Vitocal 200-A)
Cylinder with external heat exchanger (cylinder loading system) and heating lance
During the loading process (no draw-off), cold water from the cylin-
der is extracted from the lower section by means of the cylinder
loading pump. The water is heated in the heat exchanger and resup-
plied to the cylinder via the heating lance mounted in the flange.
The generously sized outlet apertures in the heating lance result in
low flow velocities, which in turn provide clear temperature stratifica-
tion inside the cylinder.
DHW booster heating is possible if an additional immersion heater is
installed (on site).
Design information
(cont.)
VITOCAL
VIESMANN
125
5831388